Page 14
Instruction Manual, Gunclean Toftejorg TZ-750 Fixed & Portable
Standard machines and machines delivered with ATEX certification
in accordance with Directive 94/9/EC
IM-TE91A400-EN7
Installation and Normal Operation
(continued)
Subject to the intended use environment and any inhouse user requirements or policies, a liquid threadlocker
such as Loctite No. 243 or equivalent could be used. Other methods could be acceptable and subject to
customer preference. For detailed instruction on pre-cleaning and application of the product carefully follow
the instruction on the used locking system.
1. Clamp machine firmly in a vice: Place
machine on top of vice with Hub w. nozzles
down wards as illustrated on the figure.
Clamp on the Hub. To protect machine use
rubber jaws on the vice.
2. Set torque wrench at the specified tightening
torque.
3. Tighten nozzle with the torque wrench.
Recommended tightening torque: 75 Nm
Check that the machine is in operating condition by inserting 3/16" hex Screwdriver (tool No. TE134A)
in screw in top of Turbine shaft and easily turn Turbine shaft clockwise. If any resistance is recognised,
the machine should be disassembled to localise the cause.