Page 20
Instruction Manual, Gunclean Toftejorg TZ-750 Fixed & Portable
Standard machines and machines delivered with ATEX certification
in accordance with Directive 94/9/EC
IM-TE91A400-EN7
Maintenance and Repair
(continued)
Top Assembly
Disassembly
1.
Remove Lockingwire (pos. 19)
2.
Remove Screws (pos. 34). Loosen with Key (tool No. TE135) and unscrew with Screwdriver (tool No.
TE135A) through holes in the Flange.
3.
Lift off Flange (pos. 1)
4.
Remove Screw (pos. 17), Spring washer (pos. 16) and Washer (pos. 18). To secure Impeller against
rotation, insert carefully Screwdriver (tool No. TE135A), through Impeller (pos. 4) into a hole in the
Stem.
5.
Pull off Impeller (pos.4).
Reassembly
1.
Reinstall Impeller (pos. 4). Make sure that Impeller is correctly rotated to be pushed onto Turbine shaft.
Do not try to hammer Impeller in position, as this will damage Slide bearing under Turbine shaft.
2.
Mount Washer (pos. 18), Spring washer (pos. 16) and Screw (pos. 17) and tighten. To secure Impeller
against rotation insert carefully Screwdriver (tool No. TE135A) through Impeller (pos. 4) into a hole in
the Stem.
3.
Mount Flange (pos. 1). Rotate Flange to align holes in Flange and Stem.
4.
Mount Screws (pos. 34) with Screwdriver (tool No. TE135A) through holes in the Flange. Tighten with
Key (tool No. TE135).
5.
Secure with Lockingwire (pos 19).
Summary of Contents for Gunclean Toftejorg TZ-750