20
6. Maintenance
6.2 Assembly of
Think
Top
®
Basic
Step 1
Place sensor unit in base and tighten screw (torque: 1 Nm).
Step 2
1. Assemble base with adapter by turning adapter slightly
anticlockwise and tighten the three screws (1.9 Nm).
2. Replace X-ring (16).
CAUTION!
Do
NOT
twist the X-ring in the groove!
The X-ring is not square; The highest (h) part
must be placed as fig.
Note:
Turn banjo
connection!
Step 3
1. Replace solenoid valves (up to three) with new ones.
2. Tighten screws (0.2 Nm).
Step 4
1. Replace X-ring (9).
2. Replace cover of
Think
Top
®
Basic
and tighten the three screws (0.6 Nm).
CAUTION!
Do
NOT
twist the X-ring in the groove!
The X-ring is not square; The highest (h) part
must be placed as fig.
Study the instructions carefully.
Handle scrap correctly.
Always keep spare X-rings in stock.