Installation and Normal Operation
Instruction Manual, Alfa Laval Toftejorg SaniMidget SB
Page 9
IM-TE91A720_EN2
Installation and Normal Operation
General Installation Instructions
It is recommended to install a filter with mesh size 250 µm (0.01”) in the supply line in order to avoid
particles, scale etc. from clogging the inside of the cleaner.
Before installation, all supply lines and valves must be thoroughly flushed
to remove remains from
welding, grinding dust, scale and other foreign matter. During handling and installation handle the
machine with care in order not to damage the fine surface of the machine.
Randomly selected SaniMidget SB machines are tested at the factory before shipping, in accordance
with “Test Requirements for SaniMidget SB/3-A”
.
Note:
The machine shall be installed in accordance with national regulations for safety and other
relevant regulations and standards. In EU-countries the complete system must fulfil the EU-Machinery
Directive and depending of application, the EU-Pressure Equipment Directive, the EU-ATEX Directive
and other relevant Directives.
Pos. 1
Connector
Pos. 2
Rotor
Pos. 3
Stator
Pos. 4
Clip
Important
information:
Recommended installation position:
The Rotary Spray Head tank cleaning machine should be installed in vertical position
(upright or upside down). If the machine is installed in any angle to vertical, the life
time may vary. If installing at an angle to vertical, ensure that the clip cannot fall out
by gravity. To maintain drainability, the device should not be tilted more than 25° to
vertical.