18
Figure 21.
Upon termination of the stabilization stage (the standard duration is about 2 seconds), the control of the electronic
unit goes to an operation mode, sowing the selected heating power (which may be changes by means of the
buttons 5 and 6) and the ambient temperature Figure 22.
Figure 22.
In this stage the buttons 5 and 6 adjust the stove energy from 1 to 5, provided that the ambient temperature is less
than the determined set temperature*.
On the contrary, the heating energy is set to a minimum.
* Actually, the stove is set to an ambient temperature. After reaching the desired temperature (manually adjusted –
look at the chapter with description of the modification of ambient temperature), the stove adjusts its operation to a
minimum and in that case it is not possible to change the heating energy.
Of the pellet d fuel does not ignite, the stove will try once more to ignite the fuel. If the pellet ignition does not
succeed once again, this will be indicated with an alarm.
The speed of the device for air suction and the fan, as well as the time required for furl ignition through the heating
element, are parameters which can be adjusted only by authorized professional repairmen, factory exports.
Once connection to the power supply is established, upon stoppage of electricity for a certain period of time, the
control of the electronics enables discharge of the remaining smoke with an increased speed of the air suction
device and then the display shows the following message
"COOL FIRE".
Once the cooling is over, then the fuel
ignition starts once again.
IMPORTANT NOTICE
The stove normally switches on after about 15 minutes, with a good quality of the pellet fuel and with an ambient
temperature of 11 degrees. If the ambient temperature is lower and the spark plug functions normally, cancellation
of the stove ignition may occur. If this happens, you should switch off the stove by pressing the button 4. Than take
remove and empty the cast burner (figure 14) where the pellets fall and combust. Return the cast burner to its
position in the stove and once again start (restart) the stove by pressing button 4 for few seconds.
•
In order to bypass i.e. to circumvent the stage of starting of the stove,
press button 6 with a duration of 2
seconds. This leads directly to the operational stage of the stove. Note: Use this only when the stove is
switched on and with an active flame in the stove.
•
In order to change the set ambient temperature
(this is the desired temperature of the room where the
stove is located), at any moment press the button 3 and use the buttons 2 and 1 to adjust the temperature
indicated on the lower display. When the button 3 is pressed, the lower part of the control board indicates
the set ambient temperature (the one you would like to achieve).
•
In order to manually set the room ventilation, press button 3. The indication "SET X" is shown on the
display where the flickering letter X represents the speed of the exchanger ventilator, which may be
changed by using the buttons 5 and 6 and which may have the following values:
A = AUTOMTIC
speed of the exchanger follows the real indicated energy
1 = SPEED 1 (speed 1)
2 = SPEED 2 (speed 2)
3 = SPEED 3 (speed 3) are all possible manual fan adjustments
4 = SPEED 4 (speed 4)
5 = SPEED 5 (speed 5)
•
In order to check the stove temperature,
press button 1. The lower display on the control board shows the
temperature, while the upper display shows the number of rotations of the smoke suction motor.