22
located in the lower back part, above the main switch (0-1) Figure 10 and then press the button 4 in a duration of 3
seconds until the stove returns back to it ON (switched on) position. The upper thermostat blocks the stove
operation when the stove chamber heats at 180°C and the lower one when the case of snail transmission heats at
80°C.
NOTE: If one of these two last alarms is active, make sure that the chamber is not clogged with ash and that the
flue is not partially clogged.
Figure 27
9
Alarm for failed ignition
It triggers when the ignition stage failed and the following message appears „
ALAr Acc no
“ (Figure 28). The
switching off procedure immediately activates.
Figure 28
9.4.6. Alarm for power outage
When the stove is switched on, a power outage stops the operation of the electrical devices on the stove. When the
power supply returns, an alarm signalization occurs as shown in figure 29:
Figure 29
9.4.7. Alarm ALAr Fan (alarm for discharge fan)
If the smoke discharge fan does not function well, an alarm occurs –
ALAr FAn FaiL
(Figure 30).
The stove begins the procedure of switching off while the alarm is on.
Figure 30
9.4.8. ,,StoP FirE“ (it is not an alarm)
StoP FirE
“
mode can be activated in adjusted intervals, during normal operation. Cleaning of the stove is
performed.
A message „StoP FirE“ is shown (Figure 31).
Figure 31
no rEtE
dEP
FAn FAiL