background image

 

 

During  combustion,  thermal  energy  is  released,  which  significantly  influences  increasing  temperatures  of  surfaces,  doors, 

handles,  glass  and  exhaust  gases.  Avoid  contact  with  those  elements  if  you  are  not  wearing  protective  equipment  (including  a 
protective glove). 

Ensure that children are aware of the risks and keep them away from the stove during operation. 
Packaging components  can be dangerous for children and adults with disabilities. There is a risk of injury. It is necessary to 

remove all components in a safe place. 

Replacement  parts,  other  than  our  tested  original  parts,  must  not  be  used  on  the  stove.  Alfa  Plam  is  not  responsible  for  the 

consequences of upgrading the stove. 

The air inlet or flue gas outlets must not be reduced. 
The area where the appliance is installed should have satisfactory fresh air supply. If the windows and doors are well sealed, or 

if other air-consuming appliances such as a steam cleaner, a tumble dryer, a fan, etc.., are installed in the area where the stove is 
placed, and take air, in such circumstances, air for combustion (fresh air) should be led from outside. 

Use only recommended types of fuel – namely wood logs. 
The  necessary  discharge  pressure  should  be  12  Pa  during  normal  workload.  If  the  pressure  exceedes  15  Pa,  throttle  valve 

spacer should be used for the discharge pipe (Figure 8a, and 8b) 

The  ashpan  must  not  contain  any  flammable  materials.  The  filling  level  should  not  exceed  the  height  of  lateral  sides  to  the 

ashpan. 

  Caution! 

The door and the section containing ash should always be closed (except in lighting fire, fuel supply and cleaning up ash) to 

prevent the escape of hot air. 

It  is  not  allowed  to  do  modifications  on  the  stove,  except  with  the  use  of  recommended  and  inspected  original  parts  and 

provided that the works are performed only by our service company. 

In case fire breaks out in the chimney, the stove door should remain closed with the air control damper also being closed! Never 

attempt to put out fire by pouring water down the chimney. Due to water vapor created in the chimney there is a risk of explosion. In 
case of emergency call the fire department on their emergency helpline number! 

In case of interference close all air control dampers and until the cause is eliminated do not inject new fuel into the stove! 
If you follow the installation and operation instructions, the stove shall be a reliable heat source. All possible problems could be 

solved  through  our  service  company.  In  case  of  complaints  including  problems  or  functional  errors,  please  contact  our  service 
company. They shall assist you in placing orders on spare parts. 

Do not store flammable substances or wood under the ash box, do not store firewood in it. 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Elita

Page 1: ... ELITA ELITA II This product meets the requirements of the Ecodesign Directive in terms of efficiency and air pollution level in order to contribute to the reduction of energy consumption and negative environmental impact INSTRUCTIONS FOR INSTALLATION AND USE ENG_v 2 0 ...

Page 2: ...ith the effective construction rules and regulations on firebox as well as all required local national and European standards Important notes Never manipulate fireplace by holding cast top plate The fireplace should be manipulated only while it is packed The packed stove should be brought to the location where it would be installed and only then it should be unpacked figure 1 It should be moved by...

Page 3: ...s 15 Pa throttle valve spacer should be used for the discharge pipe Figure 8a and 8b The ashpan must not contain any flammable materials The filling level should not exceed the height of lateral sides to the ashpan Caution The door and the section containing ash should always be closed except in lighting fire fuel supply and cleaning up ash to prevent the escape of hot air It is not allowed to do ...

Page 4: ...regulation 1 3 1 Primary air 1 3 2 Use of knobs on firebox door 1 4 Stove installation 2 5 Stove commissioning 3 5 1 Stove commissioning and stove operation 3 5 2 Stove maintenance and cleaning 3 6 General data 4 7 Frequently Asked Questions 4 8 The Nameplate 5 ...

Page 5: ...cted air intake The secondary air intake is on the stove door The secondary air supplies fire with the oxygen needed for clean combustion burning of previous incomplete combustion products Due to poor oxygen intake a great emission of harmful substances occurs which can lead to blockage of the flue 3 1 Primary air Reliable fuel combustion is determined based on the primary combustion air This air ...

Page 6: ... if the cast panel is used During the installation of used air drain pipe it is necessary to secure the distance of at least 50 cm away from flammable materials Before the stove is connected to the chimney it is mandatory to consult the local competent chimney sweeping organization The flue stove connection is done through the connecting elements according to SRPS M R4 031 DIN 1298 or DIN EN 1856 ...

Page 7: ...vement of certain amount of smoke If adding fuel the door should be opened carefully to eliminate smoke This method stops smoke from entering the room Nominal heat output is achieved with the following fuel quantities and the primary air control damper settings Fuel type Fuel quantity Combustion time Air control on the stove door near the ashpan kg h Degree wood logs 1 8 1 15 cm open The stove may...

Page 8: ...n high temperatures such sediments could ignite with severe consequences to the chimney and the entire house caused by improper behavior Figure 8 Shaking of the grate is performed via the knobspresented on figure 5 6 General data If you adhere to the instructions for installing and use of the stove this stove will be a reliable source of heat All problems with Your stove can be resolved by our ser...

Page 9: ...er the chimney size is too big and whether the flame reaches the chimney top 9 The Nameplate The nameplate is attached to the back or the bottom of stove containing serial number that should be listed for each order ...