background image

5.

 

Stove commissioning 

 
Before  the  stove  is  stoked  for  the  first  time  it  is  necessary  to  wipe  the  enameled  surfaces  with  damp  cloth  to  prevent  the 

formation of stains. Painted surfaces should not be touched and no objects should be placed on the stove, so that the paint would 
not get damaged. Finally, the paint hardens only after several hours of heating. 

After reading the operation manual, the stove is commissioned for the first time. During the first stoking you should open the 

windows because the anticorrosive protection produces unpleasant smell and smoke. That is normal phenomenon, but soon ends. 
If necessary, turn on the fan for faster air circulation. Stoke up to the maximum temperature load, 1 hour at least. If the maximum 
temperature is not reached during the first stoking, problems with unpleasant smell might occur later also. 

Sensitive  persons  such  as  pregnant  women  and  children  should  be  outside  the  room  during  this  phase.  Some  built-in  parts 

(drain pipe, ashpan door, stove door) become hot during operation, posing a risk  of burns. Handrail on the firebox door becomes 
very hot during the operation, therefore the opening and closing of the door could be done only with protective gloves (see figure 7). 

Keep children away from the stove. When the stove is stoked for the first  time, small quantities of fuel should be stoked three 

times to prevent the formation of cracks on the firesand. 
 

5.1.

 

Stove commissioning and stove operation  

 

- Open the primary air control damper to the maximum, 

 

- Open the stove door, 

 

- Insert soft wood shavings, chipboard or paper, 

 

- Place two pieces of wood across, 

 

- Ignite the paper,, 

 

- Let the wood burn 

After creating the grill, put new fuel and adjust the air regulator so that it is open 15 mm.. Never feed new fuel to flame! 

   ATTENTION  
During the stove operation and wood logs are to be placed inside, the door should have two-phase opening mechanism: first, the 
door should be open slowly and partially (up to 3 cm), so smoke could be sucked into the chimney, and then the door could be  fully 
open, but slowly to prevent ember fallout. At sudden opening, the stove door initiates the movement of certain amount of smoke. If 
adding fuel, the door should be opened carefully to eliminate smoke. This method stops smoke from entering the room

 Nominal heat output is achieved with the following fuel quantities and the primary air control damper settings. 

Fuel type 

Fuel quantity 

Combustion time 

Air control on the stove door near the ashpan 

 

kg 

Degree 

wood logs 

1,8 

15 cm open 

 

The stove may be stoked only with natural wood logs. Wood logs are placed in pieces whose length measures 32 cm. 

Remember, this stove is not an appliance used for waste incineration. 
While the stove is in function, the door has to be closed.  Slightly above the door there are openings used for cleaning glass, with 
their function to enable the air supply inside the stove. 

Lacquered, painted, veneered and impregnated firewood or wood treated with glue should not be used for the stove. In this case 

any manufacturer's warranty and liability become void. Firewood should be used dry (humidity up to 20%). As a rule, wood becomes 
dry after being stored in dry and well-ventilated place for two years. Wet wood has low calorific value and forms sediments inside 
the flue pipes, as well as the chimney. 

Under  the  most  adverse  weather  conditions  certain  hindrances  could  occur  in  the  chimney  (eg.  poor  weather  conditions).  In 

such cases the stove operation is not allowed for safety reasons. 
 

5.2.

 

Stove maintenance and cleaning  

The  stove  should  be  inspected  regularly  by  an  expert.  The  stove,  flue  pipe  and  chimney  should  be  cleaned  regularly  several 

times a year, at least once in the heating season. 

Regular maintenance and cleaning are important for proper and reliable stove operation. Maintenance of enameled or  painted 

surfaces is recommended only when the stove has cooled down. The stove should be cleaned with clean water and a soft cloth. 
Painted surfaces are cleaned with dusting brush or a dry cloth. Do not use water or damp cloths for cleaning painted stoves. The 
cleaning frequency depends on the type of fuel, namely the stove service life and the operation method.  

 

Figure 7

 

 

The ashpan (figure 7) should be regularly emptied before each stove operation. The grate should be cleaned 1-2 times weekly. 

In case of clogged air inlet with slag or other combustion residues, these should be immediately eliminated and the grate should be 

Summary of Contents for Elita

Page 1: ... ELITA ELITA II This product meets the requirements of the Ecodesign Directive in terms of efficiency and air pollution level in order to contribute to the reduction of energy consumption and negative environmental impact INSTRUCTIONS FOR INSTALLATION AND USE ENG_v 2 0 ...

Page 2: ...ith the effective construction rules and regulations on firebox as well as all required local national and European standards Important notes Never manipulate fireplace by holding cast top plate The fireplace should be manipulated only while it is packed The packed stove should be brought to the location where it would be installed and only then it should be unpacked figure 1 It should be moved by...

Page 3: ...s 15 Pa throttle valve spacer should be used for the discharge pipe Figure 8a and 8b The ashpan must not contain any flammable materials The filling level should not exceed the height of lateral sides to the ashpan Caution The door and the section containing ash should always be closed except in lighting fire fuel supply and cleaning up ash to prevent the escape of hot air It is not allowed to do ...

Page 4: ...regulation 1 3 1 Primary air 1 3 2 Use of knobs on firebox door 1 4 Stove installation 2 5 Stove commissioning 3 5 1 Stove commissioning and stove operation 3 5 2 Stove maintenance and cleaning 3 6 General data 4 7 Frequently Asked Questions 4 8 The Nameplate 5 ...

Page 5: ...cted air intake The secondary air intake is on the stove door The secondary air supplies fire with the oxygen needed for clean combustion burning of previous incomplete combustion products Due to poor oxygen intake a great emission of harmful substances occurs which can lead to blockage of the flue 3 1 Primary air Reliable fuel combustion is determined based on the primary combustion air This air ...

Page 6: ... if the cast panel is used During the installation of used air drain pipe it is necessary to secure the distance of at least 50 cm away from flammable materials Before the stove is connected to the chimney it is mandatory to consult the local competent chimney sweeping organization The flue stove connection is done through the connecting elements according to SRPS M R4 031 DIN 1298 or DIN EN 1856 ...

Page 7: ...vement of certain amount of smoke If adding fuel the door should be opened carefully to eliminate smoke This method stops smoke from entering the room Nominal heat output is achieved with the following fuel quantities and the primary air control damper settings Fuel type Fuel quantity Combustion time Air control on the stove door near the ashpan kg h Degree wood logs 1 8 1 15 cm open The stove may...

Page 8: ...n high temperatures such sediments could ignite with severe consequences to the chimney and the entire house caused by improper behavior Figure 8 Shaking of the grate is performed via the knobspresented on figure 5 6 General data If you adhere to the instructions for installing and use of the stove this stove will be a reliable source of heat All problems with Your stove can be resolved by our ser...

Page 9: ...er the chimney size is too big and whether the flame reaches the chimney top 9 The Nameplate The nameplate is attached to the back or the bottom of stove containing serial number that should be listed for each order ...

Reviews: