Figure 1 

 

             Solid fuel furnace 

 

1.  Furnace panel 
2.  Door of hearth 
3.  Furnace coat 
4.  Ash compartment  
5.  Grate vibrator 

 

1.  Technical data 

                                                                                            

VULKAN                    VULKAN S 

      - Width………………………………………………………..340 mm………….…..340 mm 
      - Depth……………………………………………………….360 mm……………....360 mm 
      - Height………………………………………………………885 mm……………….885 mm 
      - Nominal heat power……………………………………… 4,0 kW…….………….4,0 kW 
      - Chimney pipe connection diameter  ……………………120 mm………………...20 mm 
      - Height from floor to chimney pipe axis…………………776 mm….……………776 mm 
      - Stove weight  ………………………………………………81 kg……..………….. 81 kg 
      

-

utilization rate (wood/brown coal briquettes……………………….. 84/85 % 

      - Use of chimney …………………………………...multiple 
      - Waste air current………………………………… seasoned wood:……………….3,5  g/s 
                                                                                   lignite briquette: ……………… 4,1  g/s 
      - Waste air temperature …………………………...seasoned wood:……………….260 º C 
                                                                                   lignite briquette:………………..225 º C 
      - Necessary pressure difference …………………seasoned wood:………………...12 Pa 
                                                                                   lignite briquette:………………….12 Pa 
      - CO2 content …………………………………….. seasoned wood:………………..9,61 % 
      - lignite briquette:……………..…………………………………………………………9,03 % 
 

2.  Furnace description 

 

Furnace is made of sheet-metal parts with cast iron grate, cast iron plate and cast iron door.  
Hearth is coated with replaceable fire clay plates.  
Outside coating is made of enamel.  
Fresh combustion air ducts are located on the hearth door and ash can door.  

3.  Air control 

Outside air control is located on hearth door and ash compartment door. 

 1 

 

 2 

 

 

 3 

 

 4 

 

 5 

Summary of Contents for VULKAN

Page 1: ...METAL INDUSTRY VRANJE Radni ka St 1 Tel 017 21 121 SOLID FUEL FURNACE For occasional use VULKAN AND VULKAN S...

Page 2: ......

Page 3: ...OWNER S MANUAL INSTALLATION AND OPERATION GENERAL INFORMATION...

Page 4: ...vices exhaust air from room with fireplace then fresh combustion air should be supplied from outside if needed In this regards before installing fireplace consulting authorized organization dealing wi...

Page 5: ...le Waste air current seasoned wood 3 5 g s lignite briquette 4 1 g s Waste air temperature seasoned wood 260 C lignite briquette 225 C Necessary pressure difference seasoned wood 12 Pa lignite briquet...

Page 6: ...ximum position 3 NOTE In order to avoid overheating of the furnace fuel quantity must not exceed 1 1 kg of dry seasoned wood or lignite briquette per hour when air combustion intake is properly positi...

Page 7: ...nace output installation must be carried out properly and perfect chimney function must be ensured Existing chimney pressure should be tested prior to furnace operation Testing is done with a lighted...

Page 8: ...acturer Use dry seasoned wood 20 of moisture As rule wood is dry after being stored in dry place with good air circulation for two years Wet wood uses energy for drying and has low caloric value and a...

Page 9: ...y in the warranty period only when used in accordance with this manual for connection and use The warranty shall be terminated if it is determined that if the connection of the product or repair was p...