background image

 

- Open door on ashes compartment 

 

- Close vertical grate (figure 7 position 10) 

 

- Let wood burn out and close door on ashes compartment. 

When  chippings  establish  hot  bed  of  embers,  open  door  and  add  fuel  in  the  hearth  and  adjust 
primary  and  secondary  air  control  according  to  type  of  fuel.  Never  add  new  fuel  when  there  is 
flame! 

 
 
 

 

 

 

   Air control duct on ashes compartment should be in 

               marked position  (1 - 3) (see figure 6). 
 
  

               Figure 6 
When adding fuel, open hearth door slowly to avoid smoke entering the room.  
Nominal heat power is achieved in accordance with the following table. 
 
Type of fuel 

Fuel quantity 

Combustion time 

Air  control  duct  on 
ashes ompartment 

Chimney 

draft 

control  

 

Kg 

Position 

Position 

Seasoned wood 

1,6 

1,5 

Lignite briquette  

2,25 

Use only natural seasoned wood and lignite briquettes. Seasoned wood should be in logs 17 cm 
long, or use 4 cubes of lignite briquettes. 
Polished, painted, veneered and impregnated wood or wood treated with glue is not allowed for 
use. This voids every guarantee and responsibility of the manufacturer. Use dry seasoned wood 
(20 % of moisture). As rule, wood is dry after being stored in dry place with good air circulation for 
two years. Wet wood uses energy for drying and has low caloric value and accumulates creosote 
in chimney pipes and chimney. 
Bad chimney condition (e.g. bad weather) may cause problems and smoke may not be eliminated 
completely. In such case it is not allowed to operate furnace due to security issues.  

5.2 Furnace maintenance and cleaning 

Whole furnace should regularly be checked by competent personnel. Hearth, chimney pipes and 
chimney  must  be  cleaned  regularly,  several  times  per  year  and  at  least  once  during  heating 
season.  
Regular maintenance and cleaning is crucial for proper and reliable operation of furnace. Enamel 
surfaces  should  be  cleaned  only  when  cold.  Clean  furnace  with  water  and  soft  cloth.  In  certain 
conditions,  clean  furnace  with  soap.  Cleaning  frequency  depends  on  type  of  fuel,  duration  and 
usage of furnace.  

 

         Ash can should be regularly emptied prior 
o       e ach operation (figure 7, position 11). 
        1-2 times per week clean grate(figure 7, position 9). 
        In case that air duct get blocked by byproducts, 
         these must be  removed immediately.  
        In this case pull grate out and clean it (figure 7). 
 
 
Figure 7 
 
 
 
 
 

 

 

 

10 

 

11 

 

Summary of Contents for VULKAN

Page 1: ...METAL INDUSTRY VRANJE Radni ka St 1 Tel 017 21 121 SOLID FUEL FURNACE For occasional use VULKAN AND VULKAN S...

Page 2: ......

Page 3: ...OWNER S MANUAL INSTALLATION AND OPERATION GENERAL INFORMATION...

Page 4: ...vices exhaust air from room with fireplace then fresh combustion air should be supplied from outside if needed In this regards before installing fireplace consulting authorized organization dealing wi...

Page 5: ...le Waste air current seasoned wood 3 5 g s lignite briquette 4 1 g s Waste air temperature seasoned wood 260 C lignite briquette 225 C Necessary pressure difference seasoned wood 12 Pa lignite briquet...

Page 6: ...ximum position 3 NOTE In order to avoid overheating of the furnace fuel quantity must not exceed 1 1 kg of dry seasoned wood or lignite briquette per hour when air combustion intake is properly positi...

Page 7: ...nace output installation must be carried out properly and perfect chimney function must be ensured Existing chimney pressure should be tested prior to furnace operation Testing is done with a lighted...

Page 8: ...acturer Use dry seasoned wood 20 of moisture As rule wood is dry after being stored in dry place with good air circulation for two years Wet wood uses energy for drying and has low caloric value and a...

Page 9: ...y in the warranty period only when used in accordance with this manual for connection and use The warranty shall be terminated if it is determined that if the connection of the product or repair was p...

Reviews: