18
Minigraf M3
6.6
ORDINARY MAINTENANCE
The following operations must be performed at the times indicated below. Not observing the following instructions exonerate
the Producer from any responsibility regarding the warranty.
The operations described here below, even if simple, must be executed by qualified personnel.
The scheduled ordinary maintenance includes overhauls, checks and interventions that, to prevent stops and breakdowns,
keep the system workoing properly:
•
Lubrication state of the machine
•
Wear and tear parts state
TAB 6.6 A
6.7
EXTRAORDINARY MAINTENANCE
Listed below are the operations that need the intervention of Alfamacchine or your local distributor’s Technical Assistance
(see the paragraph 1.2). You can also use qualified staff authorized by the Producer
The extraordinary maintenance includes interventions to be performed in exceptional cases:
•
Breakage
•
Revisions
TAB. 6.7 A
6.5
LUBRICATION
Use preferably CASTROL MAGNA GC 32 or equivalent oil
Furthermore, we recommend to lubricate the driver blade every 200 working hours.
Unsuitable lubricants may cause valve seal problems (seals may become too large) and consequent Valve
jamming.
Maintenance
V-nail driver blade
Movable parts lubrication
V-nails claw heads
“L” shaped supports (V-nails
guide)
Description
Replacement every 1.000.000 V-nails shot
Lubricate the driver blade every 200
working hours
Replacement every 5.000.000 V-nails shot
Replacement every 5.000.000 V-nails shot
Machine state
Isolation for maintenance
Isolation for maintenance
Isolation for maintenance
Isolation for maintenance
MAINTENANCE
Valves and Reducers
Frontal and vertical clamping
gaskets
DESCRIPTION
Suggested replacement every 6/8 million of
V-nails shot
Replacement in case of leak of air
MACHINE STATE
Isolation for maintenance
Isolation for maintenance