14
14.3.2.1 BOILER THERMOSTAT
A menu that allows you to adjust the set water temperature in the boiler. The temperature range of the water in the boiler can
be adjusted from 30°C to 80°C. By adjusting the set water temperature, the boiler will operate at the set power until it reaches
the set water temperature in the boiler. When the set water temperature is reached in the boiler, the boiler goes into the state of
modulation and continues to operate at minimum power.
14.3.2.2 BUFFER THERMOSTAT
Menu that allows the buffer temperature to be modified. This menu is only active if the buffer is installed.
14.3.2.3 ROOM THERMOSTAT
In this menu, the set ambient probe temperature is modified. The ambient temperature setting range is from 10°C to 40°C.
14.3.2.4 SUMMER – WINTER
In this menu, the functionalities of the cooker are changed depending on the season. The display shows one of two symbols:
or
.
14.3.2.5
HEATING POWER
This menu is not active.
14.3.2.6
REMOTE KEYBOARD
This menu allows control via radio room thermostat. It must be activated by pre-setting a specific parameter.
14.3. 3.
CHRONO MENU
In this menu the system on/off times are set, i.e. the programmed operation of the cooker is set for precisely determined
periods of time.
It contains two submenus:
- Modality
- Programming
14.3.3.1
MODALITY
By entering the Chrono menu, two submenus appear, namely Modalities and Programming.
Via P4 and P6 buttons one of the submenus can be selected, and then accessed by pressing the P3 button. Entering the
Modality menu displays the following:
Description of the settings in the Modality menu:
Description
Buttons
Display on the screen
Selected modality flashes
Entering the mode of changes
P3
Selection of required modality
P4 and P6
Canceling changes and return
to the old modality
P1
Saving changes
P3
Exit menu
P1
14.3.3.2
PROGRAMMING
After accessing the Chrono Menu, there are two submenus, Modality and Programming.
Via P4 and P6 buttons one of the submenus can be selected and then accessed by pressing the P3 button. After entering the
Programming menu the following screen appears: