background image

 

 

 

 

 
 

LOCAL HEATING COOKER 

ALFA TERM 35 

 
 
 
 
 

 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

INSTRUCTION FOR INSTALLATION, SETTING, AND USE 

 
 
 
 

Summary of Contents for Alfa Term 35

Page 1: ...1 LOCAL HEATING COOKER ALFA TERM 35 INSTRUCTION FOR INSTALLATION SETTING AND USE...

Page 2: ...brown coal briquette 8 85 kW 8 85 kW Heating power transferred to water wood brown coal briquette 12 75 kW 12 75 kW REQUIRED CHIMNEY DRAFT 25 Pa FLUE PIPE CONNECTION DIAMETER 160 mm HEIGHT FROM THE F...

Page 3: ...ometer 4 Butterfly handle 13 Flue pipe connection 5 Oven door 14 Opening cover 6 Oven thermometer 15 Handle 7 Firebox door 16 Rosette cover 8 Ash pan door 17 Tertiary air regulator 9 Thermostat button...

Page 4: ...door 4 INSTALLING THE COOKER The stove can be installed in the kitchen or at any other appropriate place The substrate under the cooker should be non combustible In the event of a combustible substra...

Page 5: ...pipe Chimney connection should be vertically positioned Horizontal pieces of flue pipes over 0 5 m long should slope upwards by 10 toward the chimney Flue pipe connection flue pipes and chimney may no...

Page 6: ...201 and JUS M E7 202 Closed and open circuit diagrams are shown on Fig 7 and Fig 8 The back of the boiler and connections are shown in Fig 5 where Position 1 is an G5 4 connection with an inner threa...

Page 7: ...re in the boiler rapidly increases and overheating occurs very quickly In the open central heating system the installation of thermal fuse is not mandatory 6 2 THERMAL RELEASE VALVE WITH INSTALLED THE...

Page 8: ...be set at 2 5 to 3 bars You can fit it directly on the connection or at a distance from the connection of at least 1 m provided that there is no block valve between the boiler and the safety valve In...

Page 9: ...ump 8 Non return valve 9 Expansion vessel 10 Three way valve with attached thermostat 11 Floor heating collector 12 Cold water filter 13 Slope pressure regulator with pressure gauge 14 Hot water filte...

Page 10: ...r starts to leak and then close them Do not discharge water from the heating system even during summer because it protects the inside of the system from oxidation corrosion If you will not use the boi...

Page 11: ...rength for at least half an hour because the first to burn out are all the volatile constituents of the fuel that are usually the main causes of condensate formation in the cooker After plenty of hot...

Page 12: ...and are written on the lever By turning the lever you increase tertiary air by turning it at you can reduce the air Leave the tertiary air regulator open when the fire in the stove is lit 12 COOKING...

Page 13: ...hotplate occasionally using fine sandpaper and in the event of longer breaks apply acid free oil on the hotplate vegetable oil Remove burnt material from the cooktop with a spatula knife or treat it w...

Page 14: ...r in the installations Release air from the system 8 Circulation pump does not activate or it trips the switch No power at electrical connection Connectors are loose Check and tighten all screws at co...

Page 15: ...rs Not enough fuel has been loaded in the firebox Increase the quantity of fuel in the firebox 16 Fire is not burning regularly Low chimney draft Build a new chimney or repair the old one Connecting f...

Page 16: ...result of too high or too high voltage as well as of force majeure Defects on the device may be removed even after the expiration of the warranty using the original replacement parts for which we also...

Page 17: ...17 OUTLINE DIMENSIONS OF ALFA TERM 35 COOKER Figure 19...