General safety indications
The planning of the installation, the installation and commissioning of the solar modules may
only be carried out by persons who, due to their professional qualification, are familiar with
the installation and the proper and safe configuration. For your safety please wear a helmet,
isolating gloves and slip resistant safety shoes
Don`t do any installation or maintenance work when there are rain, snow or windy conditions.
The installation should be done on an underground with verifiable static conditions.
The assembly is to be mounted over a fire resistant roof covering rated for the fire application
of alfasolar modules.
Be aware that you don`t through anything on the solar module! Prevent your solar module of
any mechanical influence on the front- and backside. Do not install solar modules which are
damaged!
Touching live parts of the solar module such as terminals can cause burns, sparks or a fatal
death both at connected and at disconnected modules.
Solar modules generate electricity as soon as sufficient direct or indirect sunlight reaches the
surface of the module. Aeries connection of solar modules (addition of voltages) can cause
voltages above the low voltage of 120 Vdc. (
see Chapter 3.4.11 Tab.1 Date and limit values of
) specifies the maximum number of series connected solar module which shall not
be exceeded, even not under low ambient temperatures.
Do not cover the water outlet holes in the module frame. If water remains in the frame there
is a risk of frost damage. Please do not drill holes into the module frame. This could affect the
stability of the frame and cause corrosion. Don´t touch the module with bare hands. The edg-
es could cause injuries to your hands.
Protect the cables during transportation and installation to any mechanical shock.
Please make sure that the environment of the installations site does not cause a negative im-
pact. In the following areas precautionary measures should be taken in order to ensure a high
degree of reliability and safety: snowy regions, cold regions, windy areas, coastal or offshore,
areas with increased risk due to salt water or ammonia, islands or desert areas.
In areas with high amounts of snow preventive measures against bending under load shall be
taken.