ALF-21E-SOFTCODEC
9
Auto Control:
When detecting a video input signal (5V or TMDS), automatically send
CEC and RS232 commands to turn on the display device. When not detecting any
video signal within the setting time (default 10mins), automatically send RS232 and
CEC commands to turn off the display device.
The RS232 command can be set by sending commands, please refer to the
or more details.
5.4 EDID Setting
The Extended Display Identification Data (EDID) is used for the source device to match
its video resolution with the connected display. By default, the source device obtains its
EDID from the first connected display. Meanwhile, since the displays with different
capabilities are connected to the switcher, the 4-pin DIP switch on the front panel can
be used to set the EDID to a built-in fixed value. Use the following table to determine
the setting for the 4-pin DIP switch for specific video resolution and audio capabilities.
The switch represents “
0
” when in the lower (
OFF
) position, and it represents “
1
” while
putting the switch in the upper (
ON
) position.
Switch Status
Video Resolution
Audio Format
0000 (Default)
EDID pass-through
0001
1280x720@60Hz RGB 4:4:4
Stereo
0010
1920x1080@60Hz
DVI
0011
1920x1080@60Hz 2D
PCM 2.0
0100
1920x1080@60Hz RGB 4:4:4
Stereo
0101
1920x1080@60Hz RGB 4:4:4
High Definition
0110
1920x1200@60Hz RGB 4:4:4
Stereo
0111
3840x2160@60Hz RGB 4:2:0 HDR
Stereo
1000
3840x2160@60Hz RGB 4:2:0 HDR
High Definition
1001
3840x2160@60Hz RGB 4:4:4
Stereo
1010
3840x2160@60Hz RGB 4:4:4
High Definition
1011
User-defined EDID (Please refer to the
6.2.3 User-defined EDID
)
1100
1101
1110
1111