background image

�  Range 

Installation Instruction 

Concealed Thermostatic Shower mixers 

This instruction manual is for our 4-way thermostatic shower mixer 5,  100200758** and 6

100200833**, and for the 

2-way and 3-way shower mixers 1,  100200756**, 2,  100200831**, 3,  100200757** and 4,  100200832**,

please just refer to this and make proper adjustments.

No. 

Model No.s 

Description 

100200756** 

Concealed Thermostatic 

100200831** 

Shower Mixers (2-way) 

100200757** 

Concealed Thermostatic 

100200832** 

Shower Mixers (3-way) 

100200758** 

Concealed Thermostatic 

,�� 

\;_�� 

.. .. 

.

100200833** 

Shower Mixers (4-way) 

1 )Product Image 1: 

2) )Product Image 2:

13 

TI

1.Application:

The concealed Thermostatic shower mixers are applicable for

storage-type and low-pressure soler heating systems.

2.Specifications:

*

Product standard: QB2806-2006; 

The hot and cold water supplying flowrate can be adjusted or shut-off

by vertically rotating the screws on the front of the concealed rough-in body.

*

With thermostatic cartridge to guarantee stablized water temperature.

With safty lock to prevent scalding.

With automatic shut-off function in case of short-supply of cold water. 

3.Water pressure:

Min.: 0.14MPa. 

Suggested range: 0.14-0.5MPa.

When under pressure of 0.5MPa, pressure-reducing is necessary.

Max.: 0.86MPa.

Strength testing pressure: 2.5MPa,

List of Components 

Pcs 

List of Components 

Pcs 

List of Components 

1. Rough-in body 

6.Plate 

11.Temperature 

2. Swelling Plastic 

7.Cover 

handle 

Button 

a.Button 

12. Volume handle 

3.Positioning bar 

9.Screw 1 

13. Allen key 

4.Tapping screw 1 

1 O.Diverter handle 

14. Instruction 

5.Tapping screw 2 

4. Flowrate:

15. SL/min  when cold and hot water pressure at 0.3MPa.

6.5Umin  when cold and hot water pressure at 0.07MPa. 

5.Water temperature:

When hot water supplying temperature at 50'C-82'C

and cold water supplying temperature at 3. 9'C-27'C,
mixing water temperature can be adjusted from 38

°

C to 49

°

with 

±2'C 

tolerance. 

6.Rough-in installation:

Check list of components. 

Prepare wall and dig curves accordingly.

Fix rough-in body properly. 

7. Important:

The diverter of the mixing water is not a shut-off diverter. 

Welding temperature shall be carefully controled.

*

Check lightness of joints.

*

Flush the pipes.

*

Hot water supplying connect to the left, and cold to right.

-1-

Pcs 

Reviews: