Start-up
You receive a completely assembled magnetic core drilling machine and detailed operation manual. Please check
the condition of the goods on receipt for any transport damage, and make sure the delivery is complete. Otherwise
contact the manufacturer immediately.
Always read the operation manual before using the device for the first time!
1.
First, check the cable and plug for damage, then insert the plug in the mains socket.
2.
Insert the core drill in the tool holder on the working spindle of the motor and check the stable, exactly
positioned clamping of the tool (see back).
3.
The lever is pointing upwards and the switchable permanent magnet is deactivated so that you can position
the machine. A slight magnetic pre-tension helps with alignment of the machine on vertical walls or for
overhead work. Secure the drilling unit using the safety belt when working on walls and ceilings.
4.
Press the lever down as far as it will go. Make sure that the safety tab audibly latches into place.
5.
As soon as the sensor LED lights up green or flashes red, activate the motor by pressing the MOTOR
ON key on the operating panel at the side.
6.
Turn the star handle to lower the motor and the rotating drill slowly to the work piece. Ensure sufficient cooling
during the drilling process.
7.
When you have finished drilling, move the motor upwards by turning the star handle. Deactivate the motor by
pressing the MOTOR OFF key on the operating panel.
8.
Once the motor has come to a complete standstill, remove swarf and other drilling waste.
9.
To deactivate the permanent magnet, press the black safety tab inwards using the ball of your hand and lift
the lever up.
10. Then clean the underside of the magnet of swarf or any other residue stuck to it.