5
Device description
The magnetic core drilling machine can be attached to ferromagnetic work pieces using a mechanically switchable
permanent magnet. For this purpose, the magnet lever must be pressed downwards and the safety tab must latch
into place correctly. The motor can be switched on and off using the large keys on the operator panel. The LEDs on
the motor operating panel and the machine clearly indicate the operating state of the motor and the magnet’s
holding force. A self-adjusting dovetail guide which the motor is attached to can be vertically adjusted using the star
handle. The type plate and an attachment location for the Allen keys included can be found on the back of the
machine.
A) Drive motor
G) Safety tab
1 – Motor ON
B) MT2 arbor
H) Operating panel
2 – LED for motor control
C) Slide and setting screws
for adjustment on the back
I) Lever for magnet
3 – Motor OFF
D) Magnetic foot
J) Star handle
4 – Magnetic lever ON
E) Recess for safety belt
5 – LED for magnetic field sensor
F) Main cable
6 – Magnetic lever OFF
Summary of Contents for ROTABEST RB 50 SP
Page 22: ...22 Spare Parts ...
Page 24: ...24 Exploded drawing motor ...
Page 26: ...26 ...
Page 27: ...27 ...