background image

Z-Wave+ System Integrators Guide

Document Revision: 5

Summary of Contents for DB2

Page 1: ...Z Wave System Integrators Guide Document Revision 5 ...

Page 2: ...Contents Installing the Z wave Plus Module 1 About Z wave 1 Z wave function descriptions 1 Z Wave Info 3 Supported Command Classes 3 Association Table 5 Notifications Table 5 ...

Page 3: ...iring instruction Exclusion log off is detailed in Programming instruction under Network pairing instruction This lock could be integrate with any Z wave controller from any manufacturer The lock will have limited functionality if integrated with a non secure controller Z wave function descriptions This device is a security enabled Z wave Plus product that is able to use encrypted Z wave Plus mess...

Page 4: ... lock Follow the user guide of hub to enter inclusion mode Operate on lock following guide below Enter master mode refer to programming instruction Input 8 to enter function extension settings Input 1 to join a network Log off a network Exclusion Z wave network and remove the lock Follow the user guide of hub to enter exclusion mode Operate on lock following guide below Enter master mode refer to ...

Page 5: ...e use this procedure only when the network primary controller is missing Z Wave Info Manufacturer ID Kaadas 0x021D Z Wave Device Type Door Lock keypad Z Wave Role Type Listening Sleeping Slave LSS Product ID 0x0001 Product Type ID 0x0003 Supported Command Classes Command Version Association Command Class V2 Association Group Information AGI Command Class V1 Battery Command Class V1 Device Reset Lo...

Page 6: ... Class V3 Z Wave Plus Info Command Class V2 Command Class Requires Security S0 S2 Command Class Door Lock Version 2 Alfred Z wave Plus locks only support 2 door lock modes Door Secured 0xFF and Door Unsecured 0x00 Alfred locks do not support timed operation from the door lock command class Command Class User Code Version 1 The door lock will only retain valid user code types 0x00 0x01 All other va...

Page 7: ...ally notification Notifications Table Notification Type Event Description 0x06 0x01 Manual lock operation 0x06 0x02 Manual unlock operation 0x06 0x0B Lock jammed 0x06 0x0C All user codes deleted 0x06 0x0D Single user code deleted 0x06 0x0E New user code added 0x06 0x0F New user code not added due to duplicate code update master code over z wave 0x06 0x13 Manually enter user access code exceeds cod...

Page 8: ...oth the DSK representation on the product and any DSK provided in the product packaging were to fade rub off or be lost the device would not be able to be added to a Z Wave network You can find the QR code on back side of module You may also find the QR Code and DSK on individual package of each module ...