ASDI
Operations
and
Maintenance
–
Second
Sun
–
P/N
52793
19
11.
Inspect
the
tank
heater
regulator
to
ensure
it
is
not
damaged
or
the
vent
is
not
blocked.
Make
sure
it
is
mounted
above
the
vapor
space
of
the
tank.
12.
After
connecting
to
the
battery,
check
the
voltage
inside
the
preheater
cable
connection
box
to
ensure
it
is
11
Volts
DC
or
greater.
13.
Voltage
of
the
Peltier
device,
measured
between
terminal
3
and
5,
should
be
90
mV
or
higher
to
start
the
heater
pilot
and
when
the
heater
is
warm
and
operating
this
should
measure
300
‐
400
mV
(visit
troubleshooting
information
in
Section
5).
14.
Manifold
gas
pressure
should
be
according
to
the
table
in
Figure
8.
See
Figure
3
for
gas
port
location.
15.
The
temperature
of
the
heater
face
should
be
750
–
822
°F
(399
–
439
°C).
If
the
heater
surface
does
not
reach
full
temperature
after
an
hour
of
operation
750
°F
(399
°C)
and
tank
pressure
is
less
than
55
psi
(3.8
bar),
contact
the
factory
for
instructions
(see
the
following
page).
Pilot
Mode
200
–
300
mV
Full
Heat
Mode
300
–
425
mV
Fig.
16
Fig.
17
Summary of Contents for SECOND SUN SS10
Page 11: ...ASDI Operations and Maintenance Second Sun P N 52793 11 Piping Regulator Fig 6 Fig 7 ...
Page 23: ...ASDI Operations and Maintenance Second Sun P N 52793 23 TECHNICAL ...
Page 24: ...24 ASDI Operations and Maintenance Second Sun P N 52793 ...
Page 25: ...ASDI Operations and Maintenance Second Sun P N 52793 25 130 F 130 F ...
Page 28: ...28 ASDI Operations and Maintenance Second Sun P N 52793 ...
Page 29: ...ASDI Operations and Maintenance Second Sun P N 52793 29 ...
Page 30: ...30 ASDI Operations and Maintenance Second Sun P N 52793 ...
Page 53: ...ASDI Operations and Maintenance Second Sun P N 52793 23 RENSEIGNEMENTS ...
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ...ASDI Operations and Maintenance Second Sun P N 52793 31 ...