ASDI Operations and Maintenance – TX Models – P/N: 52368
6-38
Heater
Core
Resistance
NOTE
Refer to the Bussing diagram in Appendix A for wire to wire
resistance for your vaporizer.
CAUTION
Turn off electrical power at the disconnect before proceeding.
Carefully slide out the control panel for access to the heater wire connections on
the contactor. Measure the resistance across each pair of wires. An incorrect
resistance reading indicates a faulty heater element, a wiring problem, or an
open fusible link.
Figure 14 – Heater Core Resistance Wiring Connections
READ WIRE TO WIRE RESISTANCE.
SEE HEATER WIRING DIAGRAM