ASDI Operations and Maintenance – TX Models – P/N: 52368
7-46
* - The threads between the Inlet Housing and the Outlet Housing are straight threads and are designed to be
hand tightened. Gas will NOT leak through these threads because of the seals from the two o-rings. However, the
Inlet Housing MUST be screwed all the way down for the Valve to accurately function at the set pressure. DO
NOT apply sealing agent or Teflon tape on these threads.
Refer to the table below for any replacement parts in the TORREXX Economy Valve.
QUANTITY
ASDI PART NO.
DESCRIPTION
1
5001-5023
INLET HOUSING
1
5001-5025
OUTLET HOUSING
1
5001-5024
VALVE PISTON
1
39012
VALVE O-RING (LARGE)
1
39014
VALVE O-RING (SMALL)
1
39038
VALVE SPRING
1
5001-5026
VALVE RATING PLATE
2
60204
RIVET
Mercury
Relay
The life of the vaporizer can be further extended by using a Mercury Relay. Compared to a “dry” contactor, a
Mercury Relay reduces the wear and tear each time the heater cycles. A larger explosion-proof enclosure is also
used which improves access to the electrical controls.
Mercury Relay is standard on TX240 and TX320 vaporizers in most markets. It is suitable for Class I Division 1
Group D locations and is only available in the NEC configuration. Please contact ASDI if you want to implement
this option on TX 160 or want to find out if Mercury Relay option can be used in your market.
The Mercury Relay Option can be integrated with all the other TORREXX options (i.e. Economy, Remote, etc.) In
addition, customized options such as external lamps/indicators, on/off switches are also available. Please consult
ASDI for details.
TX
Remote
Box
Includes remote start/stop capability and a status light indicating the vaporizer is ready for operation (solenoid
valve open). Connection between the box and the vaporizer is established trough the wire harness found on the
inside the vaporizer explosion proof enclosure. Remote box is intended for indoor or outdoor installation in
general purpose location.
FIGURE 21 – Remote START/STOP box
Summary of Contents for TORREXX TX100
Page 8: ......
Page 56: ...APPENDIX A TECHNICAL INFORMATION ...
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 83: ...ASCO Valve used by Algas SDI ...
Page 86: ...ASCO Valve used by Algas SDI ...
Page 87: ......
Page 88: ......
Page 89: ......
Page 90: ......