background image

Manual 

TIMY3 – Safe Driving 2 

 

 

-  5 - 

1.3  TIMY3 Software 

Available programs for the Timy3: 

Stopwatch: 

universal timing program which is suitable for several heats (run/total time) 

Backup: 

to measure time of day times (e. g. as backup-system or as time reference 

for the computer) 

PC-Timer:

 

to measure time of day times with simultaneous output of the running time 

in 1/10 seconds via the RS232 interface; ideal as an accurate timing device 

for the computer 

LapTimer: 

timing program with run times and lap times (e. g. for motor sport)

 

TrackTimer:

 

timing program for events with several lanes, e. g. athletics and swimming 

Training Lite:

 

universal training software (several intermediate times are possible) 

Training REF: 

training software with reference run (several competitors on course) 

Speed: 

speed measurement 

Commander: 

terminal for diverse subprograms (see manual) 

CycleStart:

 

program for track cycling with countdown and lap counter 

Terminal: 

terminal for judges (e. g. gymnastics) 

Track + Field: 

for measuring the wind speed with anemometer WS2, to control a concen-

tration clock and infield display board 

Parallel-Diff:

 

timing for parallel slalom (difference time of both slopes) 

Dual Timer: 

timing of two separate courses 

Timeout:

 

timing with timeout, also applicable for show jumping (with start countdown) 

Swim Trainer:

  training program for swimming 

Jumping:

 

training program for jump trials, measures jumping height on the basis of 

time between jump and landing on a contact mat (several subprograms) 

Speed-Climbing:

 timing for parallel competitions at speed climbing with false start 

Start-Liner:

 

to control a Startclock ASC3 or display boards D-LINE when using individual 

start time (e.g., Gunderson start) 

Parallel-Start:

 

to control and input start doors for opening with a different time delay 

TV-Timer:

 

simple timing program for controlling a display board or TV time flashes 

Voting: 

radio

 

judging console (WTN) for judges, voting, etc. (e.g., ski jumping)  

Safe Driving 2: 

to control a display board and speed measurement for driver training

 

CC False Start: 

false start detection for cross country skiing sprint events 

 

 

Summary of Contents for Timy3

Page 1: ...Version E220704 Manual Safe Driving 2 ...

Page 2: ...ctrician according to IEC 60364 1 Never touch the mains plug with wet hands Never touch live parts Cleaning Please clean the outside of the device only with a smooth cloth Detergents can cause damage Never submerge in water never open or clean with wet cloth The cleaning must not be carried out by hose or high pressure risk of short circuits or other damage Liability Limitations All technical info...

Page 3: ...mbol Adjustment 9 3 1 1 Mode Mode F0 9 3 1 2 Direction F1 9 3 1 3 Break Light Delay BREAK FLASH F2 9 3 1 4 Symbol Delay F3 9 3 2 Speed Measurement Adjustments 10 3 2 1 Measuring distance Dist F0 10 3 2 2 Measuring Unit Unit F1 10 3 2 3 Speed Display Delay Verz Speed F2 10 3 3 Operation 10 3 3 1 Display Time on the Display Board 11 3 3 2 Other Adjustments 11 4 Display Board 12 4 1 Display Board Int...

Page 4: ... 2 charging socket 3 ALGE TIMINGmultiport 4 connection for display board 5 connection for start impulse 6 connection for finish impulse 7 standard ALGE TIMING photocell socket 1 2 Timy3 Models Both Timy3 models are equipped with a temperature compensated quartz oscillator and there fore suited for highest accuracy The extended temperature range allows operating the Timy3 from 50 C until 20 C for s...

Page 5: ...ges e g gymnastics Track Field for measuring the wind speed with anemometer WS2 to control a concen tration clock and infield display board Parallel Diff timing for parallel slalom difference time of both slopes Dual Timer timing of two separate courses Timeout timing with timeout also applicable for show jumping with start countdown Swim Trainer training program for swimming Jumping training prog...

Page 6: ... the green OK key within 10 seconds the Timy3 switches on other wise it automatically switches off again 1 6 Switch Off You have got two possibilities to switch off the Timy3 Method 1 Press STOP OFF key for 3 seconds Display shows Really switch off Press the red OK button If you press the red OK key within 10 seconds the Timy3 switches off otherwise it returns to the pro gram Method 2 Press 2nd an...

Page 7: ...Manual TIMY3 Safe Driving 2 7 2 Setup of the System ...

Page 8: ...le After the set delay the other signals are displayed If the speed measurement SPEED is activated the speed measurement starts and appears in the Timy3 display Speed If channel C1 second photocell is triggered the speed will appear on the display panel after the set delay If the pulse from C1 is not triggered within 10 seconds after C0 the measurement is aborted The speed is shown on the display ...

Page 9: ...t or right Adjustment change arrow light 3 1 2 Direction F1 Select the direction that is shown with change everything is possible the software pics a the direction left or ritht by coincidence with left it shows only the signs of the left side of the display board with right it shows only the signs of the right side of the display board Adjustment change left right 3 1 3 Break Light Delay BREAK FL...

Page 10: ...een the two photocells can be adjusted in from 1 to 9999 m The greater the measurement distance the more precise is the speed of the measured dis tance 3 2 2 Measuring Unit Unit F1 It is possible to show the speed in km h mph or m s 3 2 3 Speed Display Delay Verz Speed F2 You can set a delay for displaying the speed between 0 and 9 9 seconds If you press the F3 button in this menu the speed displa...

Page 11: ...d If you set zero 0 then the speed will be shown until the next measurement Otherwise the display will be cleared after the duration of the delay time 3 3 2 Other Adjustments Die Einstellungen werden nach dem Aus und Einschalten nicht gespeichert PLEASE NOTE If you set red light on left the right red light will be shown since the driver has to swerve to the left ...

Page 12: ...nterface 2400 Baud no Parity Bit 8 Data Bit 1 Stop Bit Data Package 2 Byte ASCII package AX Arrow red Light Left A A Right A A4 Off A A A ASCII A 0x41 package start X State In the State Byte has each bit under 6 a function arrow on break light on red light on bit1 left arrow bit2 white light breaking light bit3 right arrow bit4 right red light bit 5 left arrow bit 6 left red light Es gibt ein Time...

Page 13: ...Manual TIMY3 Safe Driving 2 13 4 2 Display Board Connections ...

Page 14: ...Manual Timy3 Safe Driving 2 14 4 3 Mounting of the Display Board ...

Page 15: ...Manual TIMY3 Safe Driving 2 15 ...

Page 16: ...Manual Timy3 Safe Driving 2 16 Subject to changes and misprints Copyright by ALGE TIMING GmbH Rotkreuzstr 39 6890 Lustenau Austria www alge timing com ...

Reviews: