2.
Commands
In this manual, unless otherwise specified, any “key” stands for the ones on the PC keyboard.
The screen referred to is the PC monitor screen.
2-1 Command mode and Converse mode
The typical operating modes of this unit are the Command mode and the Converse mode.
It is necessary to use the command mode to set internal parameters in the EJ-41U. When the
unit is in the command mode, the “cmd:” prompt will appear on the screen. If “cmd:” does not
show up, press enter (or carriage return [CR]).
The converse mode enables the EJ-41U to transmit text as data. Use this mode for sending files
and/or text. Press the Ctrl and C keys together to return to the command mode.
2-2 General description of the commands
2-2-1: Direct commands
The commands without specific definitions or parameter settings are Direct Commands. These
are mainly used to change modes. These commands are immediate, such as D for Disconnect.
2-2-2: To set parameters
Type the command parameter name. Enter a space after the parameter name and type the new
value. Press [CR] to enter. The screen will show “XXX was YYY”(XXX stands for the parameter,
YYY for the previous value). If the parameter setting is ON/OFF, use the Y key for ON, N key to
select OFF.
2-2-3: To check current parameter settings
Type the command name only and press [CR] key. The monitor will show “XXX is ZZZ” (ZZZ
stands for current value).
2-3: Error indications
2-3-1 [?EH]
This prompt will be displayed when the command does not exist or an invalid string is entered.
2-3-2 [?BAD][?RANGE][?TOO LONG]
If the entered command does not specify the parameter [?BAD] appears. If the command exceeds
the parameter range [?RANGE] appears. If the length of a column is too long, [?TOO LONG]
appears.
2-3-3 [?TOO MANY][?NOT ENOUGH]
If the parameter value is too long [?TOO MANY] will be displayed.