background image

TIMER

Multi-functional programmable timer

● Can set 20 groups on-off program, set weekly cycle and day cycle and manually control on-off

● Have a function of countdown, and the range of time 1 second ~ 99minutes and 59 seconds

● Can manually set Daylight Saving Time(+/- 1 hour)

● Built-in lithium battery, and travel time as usual after power failure

● Can check accumulated operational time and action times

● Can auto-correct time(-3 sec ≤

t≤3 sec) every day

Technical data

Rated voltage

220VAC(85~110%)

50Hz

power failure memory:

3year

Times of switch setting:

20 groups on/off program

consumed power

≤ 5VA

Contact Form:

1 group conversion

Electrical life

10

5

times

Contact load capacity: resistance load

Resistance load
30A/ 250V AC

COSφ=1

Mechanical life

10

7

times

Countdown time

1 sec- 99min59sec

Work temperature

-10 ~ +50

O

C (non-icing

Contact resistance between contacts:

≤100mΩ

Ambient humidity

35

85

RH

Insulation resistance between contacts

≥100MΩ

Storage temperature

-10 ~ +60

O

C

Timing error

≤±2sec/day(25

)

Weight

About 150g

Wiring drawing and external dimension

Setting method

* If no display for the first time, please press “RESET”.(in addition, press “D+” and “H+” for 3 seconds, then the product will be

closed, all setting will be lost but day correction parameter, accumulated operational time and action times will not be reset.)

* If no any action procedure within 30 seconds, all set operations will exit automatically, and that will not be saved

Setting display time(present time)

Step

key

programming

1

Press

and

H+

hour increases on the screen, continuously press H+, then hours increase

2

Press

and

M+

minute increases on the screen, continuously press M+, then minutes increase

3

Press

and

D+

mark of week moves on the screen, continuously press D+ to choose week

When it starts, the timer is in 24-hour system, please press “

” for 5 seconds, the ”AM” will display at bottom-left corner of LCD,

it represent 12-hour system, press”

” for 5 seconds again, go back 24-hour system and “AM” mark disappeared.(

When the

12-hour system AM in the morning, PM in the afternoon

.)

20 groups setting of procedure switch

1. Setting program group ON/OFF time, can’t setting overlap, should be according the time sequence.(If setting same ON/OFF

time, after contact 15 seconds, will have ring a bell function ect )

2. Setting program group ON/OFF time, first step, setting present time , second step, setting the ON/OFF program, after

Reviews: