background image

1 / 6

Digital Tension Meter User Manual

Summary

1.1 Usage

Digital tension meter is a kind of tension testing equipment which is easy portable and lower

power,it’s characteristic is small size,light weight,easy to carry,wide scope of application,high

precision and so on .Apply to relay contact pressure,electronic switch ,micro auto-phone equipment

and armature pressure and so on .

1.2 Product features

1.2.1

Portable

light weight,small size,easy to carry,operation by one hand.

1.2.2

Digital display

LCD display and easy for reading.

1.2.3

Units switch

It has five units:N,Kg,Lb,Oz,g and can switch into each other.

1.2.4 Automatic show down when no operation and lower power.

1.2.5 Ultra-low standby power and long use time.

1.2.6 It can be used more than 100 thousand times continuous.

1.3 Product Specifications

Model

ATL-1

ATL-2

ATL-3

ATL-5

ATL-10

ATL-20

Max. Load

1N

2N

3N

5N

10N

20N

0.1Kg

0.2Kg

0.3Kg

0.5Kg

1Kg

2Kg

0.21Lb

0.41Lb

0.62Lb

1.03Lb

2.07Lb

4.14Lb

3.6Oz

7.2Oz

10.8Oz

18Oz

36Oz

72Oz

100g

200g

300g

500g

1000g

2000g

Load

Division

Value

0.001N

0.01N

0.0001kg

0.001kg

0.0001Lb

0.001Lb

0.001Oz

0.01Oz

0. 1g

1kg

Precision

±

0.5%

Power

AAA battery*4

Summary of Contents for ATL-1

Page 1: ...nd 1 2 2 Digital display LCD display and easy for reading 1 2 3 Units switch It has five units N Kg Lb Oz g and can switch into each other 1 2 4 Automatic show down when no operation and lower power 1 2 5 Ultra low standby power and long use time 1 2 6 It can be used more than 100 thousand times continuous 1 3 Product Specifications Model ATL 1 ATL 2 ATL 3 ATL 5 ATL 10 ATL 20 Max Load 1N 2N 3N 5N ...

Page 2: ...2 6 Use life 100 hours Dimension 128mm 66mm 28mm Net weight About 145g 1 4 The components and significance The Whole Product Structure 2 1 Outline Structure ...

Page 3: ...3 6 ...

Page 4: ... Operation 3 1 Arrangements and check before using 3 1 1 The instrument has no function of charging should be check whether the measurement rod is fixed before using should be check whether the sensor is in good response or not 3 1 2 The new instrument has built in battery isolation if the it can not start on put the battery isolation out first and then re start 3 2 The operation and instruction i...

Page 5: ... Default shutdown time is ten minutes Press SET key to enter into setting shut down automatically Press and to adjust number and then press SET key to save 3 2 4 RESET Factory reset In this menu press SET key to recover to factory resetting the instrument shut down 3 3 Test 3 3 1 Turn on 3 3 2 Choose the parameter you need 3 3 3 Choose the unit you need 3 3 4 To make test with hands or other equip...

Page 6: ... diagram of the test Attentions 4 1 Daily maintenance and repair 4 1 1 Storage and use in a dry environment 4 1 2 Do not overload Note Do not use the volatile chemicals to clean the instrument such as volatile agent diluent and alcohol Accessories and spare parts None ...

Reviews: