W 3 S E R I E S
H I G H P R E S S U R E A I R C O M P R E S S O R
©ALKIN COMPRESSORS
18
3.0 Installation
3.1 Inspection
The compressor should be inspected and checked for the following:
1.
Damage during shipping, handling etc.
2.
Check the compressor nameplate to verify the equipment conforms the working parameters.
3.
Check the electrical motor nameplate to match the available power and electrical supply.
4.
Check if the machine is filled with oil or supplied dry.
5.
Check the purifier if the cartridge is installed or not.
6.
Check if the intake filter is installed.
3.2 Location
The location where the compressor is installed determines to a considerable extent the overall performance
and service life of the unit. The compressor should be located in an area that will be dry and sheltered, well
ventilated, not exposed to high ambient temperatures, air borne contaminants such as dust, fumes, lint, vapor,
steam, gases, engine exhaust and other contaminants. Install the compressor with a minimum of 600-mm (24”)
clearance between adjacent surfaces, to insure adequate cooling and access for service.
Install the compressor on a level surface of sufficient strength to support the static weight of the equipment,
as well as the dynamic forces resulting form its operation (preferably a 6” [150 mm] concrete floor). There is
no need to bolt the vibration mounts down, except if there is more than a slight vibration. Use shims to level
and than tighten the bolts. Do not exert force bolting the subbase down, as this will created unwanted stresses
in the structure of the subbase ass’y. Use shims to take the gaps between the feet and the concrete foundation.
The canopy doesn’t need to be bolted down
3.3 Piping
Inlet Piping: If it is necessary to carry the inlet air filter to a clean location, due to excessive dirt, heat,
dampness, or toxic fumes in the near vicinity of the compressor, use 1¼” diameter good quality flexible hose;
the distance from the compressor should not exceed 3 meters (10 ft). If the inlet filter will be outdoors, protect
it with a proper hood against moisture.
Discharge Piping: If piping is required between the compressor package and the filling station, properly
selected stainless stell pipes must be used. The piping should be installed in full compliance with all Federal,
State and local codes, standards and regulations. If required, consult the manufacturer for details.
Section
3
Summary of Contents for W3 Series
Page 1: ...W3 SERIES HIGH PRESSURE AIR COMPRESSORS...
Page 2: ......
Page 4: ......
Page 6: ......
Page 10: ...W 3 S E R I E S H I G H P R E S S U R E A I R C O M P R E S S O R ALKIN COMPRESSORS 5...
Page 14: ...W 3 S E R I E S H I G H P R E S S U R E A I R C O M P R E S S O R ALKIN COMPRESSORS 9...
Page 26: ...W 3 S E R I E S H I G H P R E S S U R E A I R C O M P R E S S O R ALKIN COMPRESSORS 21...
Page 30: ...W 3 S E R I E S H I G H P R E S S U R E A I R C O M P R E S S O R ALKIN COMPRESSORS 25...