W 3 1 S E R I E S
H I G H P R E S S U R E B R E A T H I N G A I R C O M P R E S S O R
©ALKIN Kompresör Sanayi ve Ticaret Limited Şirketi
32
Dual Pressure Cylinder Filling
200 Bar Cylinder Filling Instruction
Set the pressure selection valve to 200 Bar.
Start the compressor.
Close Purifier manual drain valve if it is open.
Connect and fix the 200 Bar Filling Hose to the
cylinder.
Close the cylinder valve first.
Open the 200 bar lever on the filling valve.
Open the filling valve on the filling hose and then
the cylinder valve when the pressure reaches 150-
200 Bar on the pressure gauge on the filling hose.
Compressor will auto stop when the bottle
pressure reaches the desired pressure.
Close the cylinder valve first.
Close the filling valve. Air inside the filling hose is
automatically released by the filling valve when
the filling valve is closed.
Disconnect the cylinder
.
300 Bar Cylinder Filling Instruction
Set the pressure selection valve to 200 Bar.
Start the compressor.
Close Purifier manual drain valve if it is open.
Connect and fix the 300 Bar Filling Hose to the
cylinder.
Close the cylinder valve first.
Open the 300 bar lever on the filling valve.
Open the filling valve on the filling hose and then
the cylinder valve when the pressure reaches 250-
300 Bar on the pressure gauge on the filling hose.
Compressor will auto stop when the bottle
pressure reaches the desired pressure.
Close the cylinder valve first.
Close the filling valve. Air inside the filling hose is
automatically released by the filling valve when
the filling valve is closed.
Disconnect the cylinder.
Caution
!
If you need to fill at 200 bar, right after a filling at 300 bar, release the pressure at filling