W 3 1 S E R I E S
H I G H P R E S S U R E B R E A T H I N G A I R C O M P R E S S O R
©ALKIN Kompresör Sanayi ve Ticaret Limited Şirketi
33
2.0 MAINTENANCE
2.1 General
As you proceed through this section, it will be easy to see how simple to maintain the compressor. By
following these recommendations, you will get long and trouble free operation from your air compressor.
The following are general guidelines for periodical maintenance; specific details will be mentioned in the
following chapters. Use the
Maintenance Table
for maintenance and keeping records.
Caution!
Before attempting any maintenance or service work, isolate the compressor by switching
off the power and blowing down the pressure inside all equipment like the filters,
purifiers, pipings, etc. If a bank system exists, isolate by closing the appropriate valves.
2.2 Maintenance Procedure
DAILY
Check Oil Level, top up if necessary.
Drain the condensate from pressure equipment.
Visually verify that there is no irregularity or abnormality (loose nut, screw, unusual sounds,
loose V-belt, leaking pipes, etc.
When compressor is working, verify that the pressure on gauges are between Min. and Max.
values.
WEEKLY
Verify that inlet filter is not blocked or pierced.
For sufficient cooling, clean with a cloth flywheel, intercoolers, aftercooler and cylinders.
Check the tension of V-belt. Proper tension should be adjusted to give about 13 mm (½ ”)
deflection with a 1 kg (2 pnds) pressure is applied at the center of the belt.
Section