15
SETTINGS MENU PROGRAMMING AND DIAGNOSTICS
SETTINGS MENU PROGRAMMING
ENTERING THE SETTINGS MENU
Ÿ
Press the ENTER button twice to turn the LCD display on
Ÿ
Press the left arrow (<) button to select English
Ÿ
Use the arrows to select SETTINGS and press ENTER
Ÿ
Use the up/down arrows to scroll through the menu list
Ÿ
Press ENTER to make your selection
Ÿ
Use the left arrow (<) to go back to the previous screen
SETTING THE TIME AND DATE
Ÿ
From the SETTINGS menu, select TIME & DATE and press ENTER
Ÿ
Move the cursor to TIME and press ENTER
Ÿ
Use the right and left arrows to move between hours and minutes
Ÿ
Use the up and down arrows to change the time
Ÿ
Press ENTER to save the time
Ÿ
Move the cursor to DATE and press ENTER
Ÿ
Use the right and left arrows to move between the month, day, and
year.
Ÿ
Use the up and down arrows to change the date
Ÿ
Press ENTER to save the date
Ÿ
Use the up and down arrows to scroll through the days of the week
Ÿ
Press ENTER to save the day
SETTING MOTOR SPEED
Ÿ
From the SETTINGS menu, select SPEED and press ENTER
Ÿ
Use the up and down arrows to scroll through the sub menu and
press ENTER to edit desired setting
Ÿ
The MAX SPEED can be adjusted between 50-100%. Use the up
and down arrows to change the percentage and press ENTER to
save
Ÿ
The ACCELERATION can be set at slow, medium, and fast. Use the
up and down arrows to change the setting and press ENTER to
save
Ÿ
The SLOW/DOWN can be adjusted between 70-95%. Use the up
and down arrows to change the percentage and press ENTER to
save
SETTING MOTOR POWER
Ÿ
From the SETTINGS menu, select POWER and press ENTER
Ÿ
Use the up and down arrows to scroll through the sub menu and
press ENTER to edit the desired setting
Ÿ
The TORQUE can be set at low, medium, or high. Use the up and
down buttons to change the setting and press ENTER to save
Ÿ
The CURR. SENSE can be set at threshold (THLD) for normal
operation or progressive (PRGV) for windy areas. Use the up and
down arrows to make selection and press ENTER to save
SETTING THE 7 DAY TIMER
Ÿ
From the SETTINGS menu, select 7/DAY TIMER and press ENTER
Ÿ
Select the EVENT you would like to program and press ENTER
Ÿ
Use the arrows to select the ACTION and press ENTER to save
Ÿ
Use the arrows to set the time for the action and press ENTER to
save
Ÿ
Set the days you would like the action to take effect. Use the up and
down arrows to scroll through the days and the right arrow to toggle
the day on/off
Ÿ
Repeat the steps above for each event (up to 10)
SETTING THE LEAF DELAY
Ÿ
From the SETTINGS menu, select LEAF DELAY and press ENTER
Ÿ
Press ENTER to select which leaf needs the delay. The cursor will
blink on the left side of DELAY LEAF
Ÿ
Use the up and down arrows to toggle between ONE/TWO leaves
and press ENTER to save
Ÿ
Select DELAY and press ENTER. Use the up and down arrows to
set the delay between 0.00 and 6.0 seconds.
SETTING THE AUXILIARY RELAY
Ÿ
From the SETTINGS menu, select AUXILIARY RELAY and press
ENTER
Ÿ
Use the up and down arrows to select the function and press
ENTER
Ÿ
If PRE-WARN SIGNAL was selected, you must set the delay. use
the up and down arrows to set the pre-warn delay and press ENTER
to save.
Ÿ
NOTE: An asterisk (*) will appear on the selected function
SETTING THE SERVICE CYCLE
Ÿ
From the SETTINGS menu, select SERVICE CYCLE and press
ENTER
Ÿ
Press ENTER to set the number of cycles
Ÿ
Use the right and left arrows to move the cursor and the up and
down arrows to change the number. Press ENTER to save
SETTING THE LIMIT SWITCH CONFIGURATION
Ÿ
From the SETTINGS menu, select LIMIT SW CONF. and press
ENTER
Ÿ
Press ENTER to edit the setting. Use the up and down arrows to
toggle between INDEX and BEMF and press ENTER to save
RESETTING BACK TO DEFAULT
Ÿ
From the SETTINGS menu, select SET TO DEFAULT and press
ENTER
Ÿ
Use the up and down arrows to select the parameter you would like
to set back to factory default and press ENTER
Ÿ
DEFAULT all will set every parameter back to factory settings.
_______________________________________________________
DIAGNOSTICS MENU
ENTERING THE DIAGNOSTICS MENU
Ÿ
Press the ENTER button twice to turn the LCD display on
Ÿ
Press the left arrow (<) button to select English
Ÿ
Use the arrows to select DIAGNOSTICS and press ENTER
Ÿ
Use the up/down arrows to scroll through the menu list
Ÿ
Press ENTER to make your selection
Ÿ
Use the up and down arrows to scroll through the sub menus and
gather data
Ÿ
Use the left arrow (<) to go back to the previous screen
Summary of Contents for TORO 24