21
MODE
CLOSE-LIM2
OPEN-LIM2
CLOSING
OPENING
CLOSE-LIM
OPEN-LIM
BATT-LOW
ALARM
MON_FAULT
AC/PWR ON
LED DIAGNOSTICS
STOP CMD
ON when the STOP CMD input is activated.
(open circuit to common)
RADIO
ON when the RADIO input is activated.
(closed circuit to common)
EXIT
ON when the EXIT input is activated.
(closed circuit to common)
PHANTOM
ON when the PHANTOM input is activated.
(closed circuit to common)
SAFETY
ON when the SAFETY input is activated.
(open circuit to common)
CLOSE CMD
ON when the CLOSE CMD input is activated.
(closed circuit to common)
MON_CLOSE
ON when the MON_CLOSE input is activated or when a
device is not installed.
(open circuit to common)
MON_OPEN
ON when the MON_OPEN input is activated or when a
device is not installed.
(open circuit to common)
TIMER
Blinks when the timer is counting down to close
automatically.
MODE
Blinks
once
every two seconds when there is a problem
with the
motor hall sensor
feedback. Blinks
twice
every
two seconds when a
motor overload
is detected. Blinks
three times
every two seconds when the game is
jammed
.
CLOSE-LIM2
ON when the CLOSE LIMIT on MOTOR 2 is activated.
OPEN-LIM2
ON when the OPEN LIMIT on MOTOR 2 is activated.
CLOSING
ON when the board is sending power to MOTOR 1
and/or MOTOR 2 for the closing direction.
OPENING
ON when the board is sending power to MOTOR 1
and/or MOTOR 2 for the opening direction.
CLOSE-LIM
ON when the CLOSE LIMIT on MOTOR 1 is activated.
OPEN-LIM
ON when the OPEN LIMIT on MOTOR 1 is activated.
BATT-LOW
ON when the batteries are low.
ALARM
Blinks every 30 seconds (alarm will also beep) when the
batteries are low, bad, or disconnected. Turns on for 5
minutes (alarm also goes off) when the operator goes
into shut down mode due to the gate hitting an
obstruction (ERD).
MON_FAULT
ON when there is an issue with the monitored
entrapment device. Check device wiring and alignment.
AC/PWR ON
ON when AC power is on.
STOP CMD
RADIO
EXIT
PHANTOM
SAFETY
CLOSE CMD
MON_CLOSE
MON_OPEN
TIMER