PLUG-IN DETECTOR INSTALLATION
Ÿ
The Toro operator comes equipped with the pre-wired LPR-1 loop rack for safety, phantom, and exit plug in
loop detectors, making installation quick and efficient.
Ÿ
Hardwired loop detectors with harnesses can also be installed. The circuit board has 12 VDC and 24 VDC
terminals to power the detector of your choice. See “Accessory Connections” page for wiring instructions.
Ÿ
Wire one or more safety devices in series with the loop rack wires. To do this, remove the white wire (N.C)
from the loop rack off of the SAFETY terminal on the circuit board and wire nut to the COM of the additional
device. The N.C. contact of the additional device will now go on the SAFETY terminal of the board.
Ÿ
IMPORTANT:
Use different frequencies for each loop detector to eliminate interference.
12VDC
GROUND
EXIT
PHANTOM
SAFETY
DC BOARD
LOOP RACK
EXIT
SAFETY
PHANTOM
GROUND
12-VDC
RED
BLACK
GREEN
BROWN
WHITE
WIRE COLOR
5
5
MOTOR 1
MOTOR 2
MON_12/24VDC
MON_CLOSE
MON_OPEN
ST
OP
CMD
COMMON
COMMON
CLOSE CMD
Exit Loop
Phantom Loop
Safety Loop
See side for
Jumper setting
Loop Connections
Exit
Loop
Loop
Loop
Safety
Phantom
24VAC/
12VDC
Ground
Exit
Phantom
Safety
Outside Safety loop
Inside Safety loop
Center Phantom loop
Exit loop
WHEN USED
COMPATIBLE PLUG IN DETECTORS
BRAND
MODEL
JUMPER SETTING
RENO A&E
EDI
DIABLO
H2
LMA-1800
DSP-40S
OFF
OFF
ON
NP2-ES
NORTHSTAR
ON
DIABLO
DSP-55
OFF
DIABLO
DSP-50
OFF