OWNER’S MANUAL
2) No electricity is generated at receptacle
1. AC protector
Check to make sure the AC protector is in the position.
2. Appliance
Check whether the appliance has been connected to the generator
when the engine is starting. Disconnect the appliance from receptacle.
3. Control box
Check wire leads in control box for loose connections.
Secure connections if necessary.
2. Engine oil system Insufficient
- Oil level is low-Add engine oil.
3. Electrical system
Poor spark
- Spark plug dirty with carbon or wet-
Remove carbon or wipe spark plug dry.
- Faulty ignition system-Consult dealer.
4. Compression insufficient
- Worn out piston and cylinder-Consult
dealer.
- Loose cylinder head nuts-Tighten nuts
properly
- Damaged gasket-Replace gasket.
5. Choke lever
- If the choke lever is not in proper position, set it to close position.
(After the engine runs , set the choke lever to open position.)
13