Page -2-

 GENERAL HAZARD WARNING:

FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN
DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN,
ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.

ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.

IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT
THE MANUFACTURER.

 WARNING:  FIRE, BURN, INHALATION, AND EXPLOSION HAZARD.  KEEP SOLID COMBUSTIBLES, SUCH AS

BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED
BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE
COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN
CHEMICALS.

HEATER SPECIFICATIONS

Type of Gas:

For use with Propane Only

Gas Supply Pressure

to  regulator

Maximum:  Bottle Pressure

Minimum:  5 psig (34.5 kPa)

regulator  out

28" W.C. (6.97 kPa) (11" W.C. (2.74 kPa) for 30-FAS/SPC-30

Electrical Input:

115V, 60 Hz, 1Ø, 3a

Minimum Operating Voltage:  100V

Ignition:

Direct Spark (manually operated for 30-FAS/SPC-30 heaters)

Primary Flame Control:

Thermocouple Operated Gas Valve

High Temperature Control:

240°F  (116°C)

Minimum Ambient Temp. Rating

0°F  (-17.8°C)

Model:

        30-FAS / SPC-30

     55-F/SPC-55

               85-FAC / SPC-85                           125-F / SPC-125

 Rating:

       30,000 Btu/hr

     30,000-55,000

               50,000 – 85,000                            75,000 – 125,000

    Btu/hr

             Btu/hr                                             Btu/hr

     (8.8 KW)

     (8.8-16.1 kw)

              (14.6 – 25.0 kW)                             (21.9 – 36.6 kW)

Fuel Consumption:

    1.4 lbs/hr

     1.4-2.5 lbs/hr

              2.3 – 3.9 lbs/hr                                   3.5 – 5.8 lbs/hr

    (.64 kg/hr)

     (.64-1.1 kg/hr)

               (1.04 – 1.77 kg/hr)                          (1.59 – 2.63 kg/hr)

Fuel Orifice Port No.:

    1

  18

           18

                                         18

Fuel Orifice Port Size:

     0.0730"

            0.0240”                                          0.0295"

    (1.854mm)

(0.50mm)

           (0.6024mm)                                      (0.75mm)

Heated Air Output:

    140cfm

   300cfm

          350 cfm                                          350 cfm

    (3.96 cmm)

    (8.49cmm)

          (9.91 cmm)                                      (9.91 cmm)

Average Air Temp. Rise:

     250°F (139°C)

   200°F

          200°F (111°C)                                  400°F (232°C)

WARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USE

WARNINGS

YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE

READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER.

Scheu Products Company, Incorporated

Mail: P.O. Box 250, Upland, CA 91785

Plant: 8855 Baker Ave., Rancho Cucamonga, CA 91730

Telephone: 800-325-7057

www.scheuco.com

customerservice@scheuco.com

8784

September 2003

ANSI Z83.7/CGA 2.14-2000

Models

30-FAS/SPC-30, 55-F/SPC-55, 85-FAC/SPC-85, 125-F/SPC-125

0.0196"

Summary of Contents for 125-F/SPC-125

Page 1: ...Products Company OWNERS MANUAL FORCED AIR PROPANE CONSTRUCTION HEATERS Models 30 FAS SPC 30 55 F SPC 55 85 FAC SPC 85 125 F SPC 125 RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE TABLE OF CONTENTS HEA...

Page 2: ...100V Ignition Direct Spark manually operated for 30 FAS SPC 30 heaters Primary Flame Control Thermocouple Operated Gas Valve High Temperature Control 240 F 116 C MinimumAmbientTemp Rating 0 F 17 8 C...

Page 3: ...thdrawal ask your propane dealer 5 Mount the propane cylinders vertically shutoff valve up Secure them from falling or being knocked over and protect them from damage 6 Locate propane containers at le...

Page 4: ...resent in animal confinement buildings can mask fuel gas odor The odorant in propane LP gas and natural gas is colorless and the intensity of its odor can fade under some circumstances If there is an...

Page 5: ...LP gas supply cylinder s when the heater is not in use 4 When the heater is to be stored indoors the connection between the LP gas supply cylinder s and the heater must be disconnected and the cylind...

Page 6: ...he cylinder size required All heaters should have full cylinders good air circulation no frost on cylinders 30 000 BTU HR 11 8 kW MAXIMUM OPERATING TIME HOURS MAXIMUM OPERATING TIME HOURS MAXIMUM OPER...

Page 7: ...LVE 115V 60HZ W B 30 FAS SPC 30 Part No Color Length From To 1040 Black 6 152mm I1 Ignitor T B Line 1070 Orange 11 279mm 1 Ignitor SparkPlug 1041 White 41 2 114mm I2 Ignitor T B Return 1044 Yellow 16...

Page 8: ...Cord Assembly 1 30 6223 6223 Strain Relief Bushing 1 31 6641 6641 Terminal Board 1 32 1811 1811 Relay Assembly 1 33 3480 3480 Base 30 FAS SPC 30 PARTS Item 30 FAS SPC 30 Description Qty 34 3478 3478 B...

Page 9: ...22 6086 6086 Fan 7 1 23 2245 2246 Outer Cylinder 1 24 7094 7094 ClipHandleMounting 2 25 7095 7095 Handle 1 26 6225 6225 Snap Bushing 5 8 1 27 6226 6226 Universal Bushing 1 28 6224 6224 Snap Bushing 1...

Page 10: ...Fitting Coupling 1 20 3787 3787 Spacer TC Bracket 1 21 6127 6127 Fitting Male Connector 1 22 7285 7285 TE Valve 1 23 7404 7404 Ball Valve Variable Rate 1 24 7405 7405 Fitting Female Connector 1 25 36...

Page 11: ...ay Assembly 1 23 3275 3275 Ignitor Hi Lo 801 Mini 1 24 6079 6079 Spacer PC Standoff Nylon 3 25 6265 6265 Fitting Elbow Street 2 26 7897 7897 Ball Valve Variable Rate 1 27 7405 7405 Fitting Female Conn...

Page 12: ...om Include your name address and telephone number and include details concerning the claim Also supply us with the purchase date and the name and address of the dealer from whom you purchased our prod...

Page 13: ...Hardware Home Center Warehouse Retailer Discount Store Farm Supply Contractor s Supply Other Your Preferences How did you learn about our heater Advertising Relative friend Store display Previously o...

Page 14: ...cal support customer service and warranty registration at WWW ALLPRO HEATERS COM forAll Pro products or WWW UNVERISAL HEATERS COM for Universal products SCHEU PRODUCTS COMPANY INC ATTN MARKETINGDEPART...

Reviews: