background image

Page -5-

OPERATING INSTRUCTIONS

PREPARING FOR OPERATION

1. Check the heater for possible shipping damage. If any is

found, immediately notify the factory.

2. Follow all of the "Precautions".
3. Connect the POL fitting of hose and regulator assembly to

the propane cylinder by rotating the POL nut
counterclockwise into the propane cylinder's valve outlet and
securely tighten with a wrench.

4. Connect the hose to the heater by rotating the hose fitting

clockwise.

5. Securely tighten all gas connections.
6. Open the cylinder's gas valve and check all gas connections

with a soap and water solution. DO NOT USE A FLAME.

7. Connect power cord to well-grounded 115V, 60 Hz, 1Ø

source of power.

8. When using an extension cord, make certain that it is a 3-

wire (grounded) cord of proper wire size.

START

1. Before heater ignition, always allow heater fan (blower) to

run for 20 seconds to purge fuel.

2. Slowly open the main valve at propane cylinder.
3. Depress the fuel valve button to light the 55-F/SPC-55, 85-

FAC/SPC-85 and 125-F/SPC-125 models. On the 30-FAS/
SPC-30 also push the ignition button until the heater lights.

4. After the heater lights, keep the gas valve button depressed

for 15 seconds then release and the heater will continue to
operate.

5. Adjust burn rate with ball valve to desired setting (55-F/SPC-

55, 85-FAC/SPC-85 and 125-F/SPC-125 only).

STOP

1. Securely close valve on the propane cylinder.
2. Continue to operate heater until all fuel in the hose has

burned.

3. Unplug the power cord.

RESTART AFTER SAFETY SHUTDOWN

1. Securely close valve at propane cylinder. Unplug heater.
2. Wait 5 minutes.
3. Restart following "Start" procedure.

MAINTENANCE AND STORAGE

1. The heater should be inspected before each use, and at

least annually by a qualified person.

2. Before each use, check the soft "O" ring seat at the bullnose

of the POL fitting. If the "O" ring is cut, scuffed, or otherwise
damaged, replace it with part number 6681.

3. Turn off the gas at the LP-gas supply cylinder(s) when the

heater is not in use.

4. When the heater is to be stored indoors, the connection

between the LP-gas supply cylinder(s) and the heater must
be disconnected and the cylinder(s) removed from the
heater and stored out of doors and in accordance with
Chapter 5 of the standard for Storage and Handling of
Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B149.1,
Natural Gas and Propane Installation Code.

SERVICING

A hazardous condition may result if a heater is used that has
been modified or is not functioning properly. When the heater is
working properly:

* The flame is contained within the heater.
* The flame is essentially blue with perhaps some yellow

tipping.

* There is no strong disagreeable odor, eye burning or other

physical discomfort.

* There is no smoke or soot internal or external to the heater.
* There are no unplanned or unexplained shut downs of the

heater.

The parts lists and wiring diagram show the heater as it was
constructed. Do not use a heater which is different from that
shown. In this regard, use only the hose, regulator and cylinder
connection fitting (called a POL fitting) supplied with the heater.
IMPORTANT Match the color stripe on the hangtag attached to
the hose assembly with the color on the label located near the
propane inlet fitting on the heater.

 

Do not use alternates. For

this heater, the regulator must be set as shown in
"specifications". If there is any uncertainty about the regulator
setting, have it checked.

A heater which is not working right must be repaired, but only by
a trained, experienced service person. To find the service center
closest to you, visit our website at www.scheuco.com.or call
(888) 619-7060.

You may also obtain in-warranty or out-of-warranty service by
taking the product to your local service center.

In-warranty products will be repaired with no charge for either
parts or labor. Please include a brief statement indicating date,
place of purchase, the nature of the problem and proof of
purchase.

Out-of-warranty products will be repaired with a charge for parts
and labor.

Models

30-FAS/SPC-30, 55-F/SPC-55, 85-FAC/SPC-85, 125-F/SPC-125

Summary of Contents for 125-F/SPC-125

Page 1: ...Products Company OWNERS MANUAL FORCED AIR PROPANE CONSTRUCTION HEATERS Models 30 FAS SPC 30 55 F SPC 55 85 FAC SPC 85 125 F SPC 125 RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE TABLE OF CONTENTS HEA...

Page 2: ...100V Ignition Direct Spark manually operated for 30 FAS SPC 30 heaters Primary Flame Control Thermocouple Operated Gas Valve High Temperature Control 240 F 116 C MinimumAmbientTemp Rating 0 F 17 8 C...

Page 3: ...thdrawal ask your propane dealer 5 Mount the propane cylinders vertically shutoff valve up Secure them from falling or being knocked over and protect them from damage 6 Locate propane containers at le...

Page 4: ...resent in animal confinement buildings can mask fuel gas odor The odorant in propane LP gas and natural gas is colorless and the intensity of its odor can fade under some circumstances If there is an...

Page 5: ...LP gas supply cylinder s when the heater is not in use 4 When the heater is to be stored indoors the connection between the LP gas supply cylinder s and the heater must be disconnected and the cylind...

Page 6: ...he cylinder size required All heaters should have full cylinders good air circulation no frost on cylinders 30 000 BTU HR 11 8 kW MAXIMUM OPERATING TIME HOURS MAXIMUM OPERATING TIME HOURS MAXIMUM OPER...

Page 7: ...LVE 115V 60HZ W B 30 FAS SPC 30 Part No Color Length From To 1040 Black 6 152mm I1 Ignitor T B Line 1070 Orange 11 279mm 1 Ignitor SparkPlug 1041 White 41 2 114mm I2 Ignitor T B Return 1044 Yellow 16...

Page 8: ...Cord Assembly 1 30 6223 6223 Strain Relief Bushing 1 31 6641 6641 Terminal Board 1 32 1811 1811 Relay Assembly 1 33 3480 3480 Base 30 FAS SPC 30 PARTS Item 30 FAS SPC 30 Description Qty 34 3478 3478 B...

Page 9: ...22 6086 6086 Fan 7 1 23 2245 2246 Outer Cylinder 1 24 7094 7094 ClipHandleMounting 2 25 7095 7095 Handle 1 26 6225 6225 Snap Bushing 5 8 1 27 6226 6226 Universal Bushing 1 28 6224 6224 Snap Bushing 1...

Page 10: ...Fitting Coupling 1 20 3787 3787 Spacer TC Bracket 1 21 6127 6127 Fitting Male Connector 1 22 7285 7285 TE Valve 1 23 7404 7404 Ball Valve Variable Rate 1 24 7405 7405 Fitting Female Connector 1 25 36...

Page 11: ...ay Assembly 1 23 3275 3275 Ignitor Hi Lo 801 Mini 1 24 6079 6079 Spacer PC Standoff Nylon 3 25 6265 6265 Fitting Elbow Street 2 26 7897 7897 Ball Valve Variable Rate 1 27 7405 7405 Fitting Female Conn...

Page 12: ...om Include your name address and telephone number and include details concerning the claim Also supply us with the purchase date and the name and address of the dealer from whom you purchased our prod...

Page 13: ...Hardware Home Center Warehouse Retailer Discount Store Farm Supply Contractor s Supply Other Your Preferences How did you learn about our heater Advertising Relative friend Store display Previously o...

Page 14: ...cal support customer service and warranty registration at WWW ALLPRO HEATERS COM forAll Pro products or WWW UNVERISAL HEATERS COM for Universal products SCHEU PRODUCTS COMPANY INC ATTN MARKETINGDEPART...

Reviews: