background image

2017 Fitness Spa

LTR20171146, Rev. D

Appendix

www.calspas.com

46

Symptom

Possible Solutions

No water pressure (no water stream 

from any jets)

Power may be switched off. Turn the power back on.

The pump may be defective. After you have tried all other troubleshooting, contact your dealer for 

assistance.

Jets surge on and off

Water level may be too low. Add water to normal level.

Pump problems

Pump runs constantly – will not shut 

off

There may be a problem with circuit board. Contact your dealer.

Noisy pump

The water level may be too low. Fill the spa with water level at 4 to 6 inches from the top.

Filter cartridge may be dirty. Clean or replace the filter.

Pump may have airlock. Remove airlock by priming spa (page 12).

The suction fittings may be blocked. Remove any debris that may be blocking the suction fittings.

Gate valves may be closed. Open gate valves. Note: Never operate your spa with the gate valves 

closed!

Air may be leaking into the suction line. Contact your dealer for assistance.

Debris may be inside the pump. Contact your dealer for assistance.

Noise may be a sign of damage. Contact your dealer for service.

Pump turns off during operation

Automatic timer may have completed its cycle. Press JETS or JETS 1 button to start the cycle again.

Pump may have overheated due to the vents on the equipment door being blocked. Make sure the 

front of the spa is not blocked to allow air flow.

The pump motor may be defective. Contact your dealer for assistance.

Pump has a burning smell while 

running

A burning smell may be a sign of damage. Contact your dealer for service.

Pump does not run

Pump may have over heated. Let it cool for an hour and try operating the spa for a shorter time.

Power to the spa may be shut off. Turn on or reset the GFCI circuit breaker. If this does not solve the 

problem, contact your dealer or a qualified spa technician.

Summary of Contents for SWIM-PRO SERIES

Page 1: ...LTR20171146 Rev D 7 20 17...

Page 2: ...Adjusting Spa Water 24 Sanitation 25 Bather Load 26 Filter Cleaning 26 Pure Cure Water Sanitizer 26 Ozonator 27 Maintenance Schedule 27 Troubleshooting Water Clarity Problems 28 Cleaning and Maintena...

Page 3: ...hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level 3 F to 6 F above the normal body temperature of 98 6 F or 2 C to 4 C above 37 C While hyperthermia has many h...

Page 4: ...n entering or exiting the spa or hot tub WARNING Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning WARNING Do not use a spa or hot...

Page 5: ...ll use it for relaxation and therapy you will probably want to create a specific mood around it If you live in a region where it snows in the winter or rains frequently place the spa near a house entr...

Page 6: ...ctrical wiring procedure Spas wired in any other way will void your warranty and may result in serious injury When installed in the United States the electrical wiring of this spa must meet the requir...

Page 7: ...0 amp GFCI and one 30 amp GFCI Four 8 AWG copper wires Use wiring diagram 1 see page 6 F 1640 BP20X One 60 amp GFCI and one 30 amp GFCI Four 8 AWG copper wires Use wiring diagram 1 see page 6 Applies...

Page 8: ...0 One 50 amp GFCI Four 8 AWG copper wires WHITE NEUTRAL BLACK HOT BLACK LOAD HOT RED LOAD HOT RED HOT GREEN GROUND GREEN GROUND GREEN GROUND GFCI Breaker Box WHITE WHITE LOAD NEUTRAL Front View of GFC...

Page 9: ...2017 Fitness Spa LTR20171146 Rev D Preparing for Your New Portable Spa www calspas com 7 Circuit Board Connection 60 Hz...

Page 10: ...2017 Fitness Spa LTR20171146 Rev D Preparing for Your New Portable Spa www calspas com 8 Circuit Board Connection 50 Hz...

Page 11: ...iltration system which can cause the pump to fail to prime If you have a skimmer like this Grip the filter by the handle and unscrew it from the canister If you have a skimmer like this Remove the bla...

Page 12: ...to the spa When the spa is filled to the correct level turn on the power at the GFCI breaker Ensure that the 120V spas are connected to the proper electrical outlet Place a garden hose in the filter c...

Page 13: ...your water clear 7 Adjust water chemistry 8 Let the spa heat up When the spa has finished priming the heater will activate Put the cover on and let the spa heat to the set temperature The system will...

Page 14: ...y while air is trapped in it Continuing to operate the pump in this way will cause damage Priming the Pump The system will enter the priming mode Priming Mode will display on the control panel In Prim...

Page 15: ...and locate the pump 3 Close the gate valve on the discharge side of the pump if your spa is installed with one 4 Turn the bleeder valve counter clockwise with a small pair of pliers until the air has...

Page 16: ...2017 Fitness Spa LTR20171146 Rev D Operating Your Spa www calspas com 14 Operating Your Spa Spa Operation...

Page 17: ...2017 Fitness Spa LTR20171146 Rev D Operating Your Spa www calspas com 15...

Page 18: ...2017 Fitness Spa LTR20171146 Rev D Operating Your Spa www calspas com 16 F F F F A...

Page 19: ...2017 Fitness Spa LTR20171146 Rev D Operating Your Spa www calspas com 17 Settings Screens...

Page 20: ...2017 Fitness Spa LTR20171146 Rev D Operating Your Spa www calspas com 18 Error Screens...

Page 21: ...2017 Fitness Spa LTR20171146 Rev D Operating Your Spa www calspas com 19 Swim Spa Workout...

Page 22: ...2017 Fitness Spa LTR20171146 Rev D Operating Your Spa www calspas com 20...

Page 23: ...water flow through the jet Rotating the face of an adjustable jet to the right clockwise will increase the amount of water flow through the jet See example shown below Neck jets adjust in the opposite...

Page 24: ...low you to divert water through jets from one side of the spa to the other or in most cases from floor jets to wall jets This is accomplished by rotating the diverter knob to the left counterclockwise...

Page 25: ...tat num voloreril in ut pratie dionull umsandio consed dolumsandit at Rat consequi tinim ilisi bla feuis euguerc ilisi Em verit iliqui endiam nulluptat lamcore minibh elestio num sandip eraesectem dia...

Page 26: ...tend to be too high and may be difficult to bring down High TA can be corrected by adding an alkalinity decreaser When the TA is balanced it normally remains stable although adding water with high or...

Page 27: ...est strip or a reagent kit See the table on the following page for the ideal range Add one or two tablespoons granulated chlorine to the spa water weekly Note that chlorine dissipation rate will be fa...

Page 28: ...aused by a dirty filter We recommend you clean your filter once a month and replace it once a year or as necessary It is extremely important that you never run the spa without a filter There is a poss...

Page 29: ...ime and duration of the filter cycle can be set according to your needs In addition a second filter cycle can be enabled Filtration time may need to be increased with heavy bather load See instruction...

Page 30: ...ill the spa Organic buildup scum ring around spa Buildup of oils and dirt Wipe off scum with clean rag if severe drain the spa use a spa surface and tile cleaner to remove the scum and refill the spa...

Page 31: ...it is free To replace the jet place it in the fitting and turn it clockwise until it is snug in place Do not overtighten the jet Spa Cover Important Keep the spa covered when not in use Covered spas...

Page 32: ...the garden hose where you would like the water to drain 4 Drain the spa Turn the valve on the hose bib fixture to open the drain When the spa has drained completely turn the valve on the hose bib fix...

Page 33: ...2 Remove the filter baskets and filters 3 Drain your spa completely as described in the instructions above 4 Vacuum water from the spa s main drain fitting with a wet dry vacuum 5 Open the bleeder va...

Page 34: ...on oil based surface protectant that is specifically formulated to protect the spa s finish from the chemicals and minerals associated with normal spa use Cleaning and Replacing the Filter Filtration...

Page 35: ...to the spa at the GFCI 2 Turn on the pump and let water run for five minutes to check for leaks 1 Water proof strainer 2 Aluminum nut 3 Lamp socket and lead wire 4 Germicidal UV lamp 5 Rubber O ring 6...

Page 36: ...king station behind the remote control The instructions contained in this manual describe only basic functions See the manufacturer s operating instructions for other features and functions Although t...

Page 37: ...ton light will turn blue 4 If they do not pair the first time repeat these four steps until it is successful The display on the remote will read WELCOME or show a mode position such as RADIO AQ DM 5UB...

Page 38: ...ected through the auxiliary input You will need a 3 5 mm audio connector as shown below There are three ways to connect your device to the media locker With the USB connection Bluetooth connection and...

Page 39: ...MODE on remote control to switch to FM radio mode If this is the first time you listen to FM radio the default frequency will be 87 5MHz as shown on the remote LCD To scan or seek FM radio channels p...

Page 40: ...device The example shown below is from an iPhone device Your device may appear differently Before you begin make sure Bluetooth in enabled on your device 1 Select Bluetooth from your device s option...

Page 41: ...ercise activity or program The Ultimate Fitness series spas feature rubber exercise bands When stretched these bands create a high tension condition Improper use or failure to connect the exercise ban...

Page 42: ...eye pad as shown Elastic bands attach to the eye pad as shown All elastic bands can also be used with either hand grips or ankle braces All elastic bands can be connected to the end of the spa and use...

Page 43: ...2295061SL MM 3 Mini Storm Massage PLUCS2297061SL 8 MFD 3 5 Maxi Flow Directional PLUCS2295091SL Appendix Jets Inserts Screw in PSD 5 Power Storm PLUCS2295131SL PSR 5 Power Storm Riffed PLUCS2295141SL...

Page 44: ...Low Profile Drain Black 640 0511 PLU21400401 Teleweir Skimmer Teleweir filter skimmer 50 sq ft 510 4601 FIL11700006 Jets Inserts Snap in SQR SQN candy cane 2 neck jet 100 shut off Candy cane w clear...

Page 45: ...ghts 1 LED light string LIT16100330 2 LED light string LIT16100331 4 LED light string LIT16100332 1 to 3 ext cord LIT16100335 LED Lights 1 to 1 port ext cord LIT16100338 Interior light with logic 7 LE...

Page 46: ...17 Foot Spas EXC12000007 Exercise Kit Attachment Plate EXC11000065 Replacement Cabinet Panels The complete selection of replacement cabinets for all models is very extensive and too lengthy for this...

Page 47: ...ough Raise temperature on topside control Cover the spa The cover will keep heat in the spa and help keep heat from escaping Make sure cover is on at all times when spa is not in use The heater elemen...

Page 48: ...may be closed Open gate valves Note Never operate your spa with the gate valves closed Air may be leaking into the suction line Contact your dealer for assistance Debris may be inside the pump Contact...

Page 49: ...or material for one year from the original date of delivery All other factory installed components not mentioned specifically including but not limited to the wood frame jets diverter valves LED light...

Page 50: ...ir or replacement Spa units in commercial use are excluded from any coverage whatsoever The spa owner accepts liability for repair work performed by anyone other than the Manufacturer or a designated...

Page 51: ...2017 Fitness Spa LTR20171146 Rev D Appendix www calspas com 49...

Page 52: ...________________________ Date Purchased _ ______________________________________________________________________ Date Installed ________________________________________________________________________...