10
NOTE: If the colors of the wires in the control cable differ from those referenced on the label or
shown in the following diagrams, make a note of what wire colors you match up at the scoreboard
and do the same at the shot clock
1. Connect the control cable leads to the appropriate terminals on the terminal block,
according to the label above the terminal block.
2. Close and secure the module access door.
At The Shot Clock:
1. Open the front panel of the shot clock by removing the screws that hold it closed.
2. Bring the control cable (from the shot clock) into the shot clock through the conduit hole
in the top of the shot clock and run it down to the terminal block located just above the
shot clock’s electronic module.
3. Connect the control cable leads to the appropriate terminals on the terminal block,
according to the connections at the scoreboard.
4. Close and secure the front panel of the shot clock.
TESTING THE INSTALLED SYSTEM
NOTE: Please refer to the INSTRUCTION MANUAL included with the scoreboard and/or shot
clocks for detailed instructions on how to connect the controller to the scoreboard and shot
clocks and for detailed controller operation instructions.
Connecting cable-controlled systems:
Connect one end of the supplied 20-ft. control cable into either of the two control cable jacks on the
back of the controller and the other into the receptacle on the supplied junction box cover installed at
the scorekeeper’s location.
Connecting wireless systems:
Connect the wireless transmitter to the controller using the interface cable already attached to the
transmitter by plugging the free end of the interface cable into either of the control cable jacks on the
back of the controller.
Testing the scoreboard system:
1. Connect the appropriate end of the 12-volt DC wall transformer to the power receptacle
on the back of the controller.
2. Plug the transformer into a live, 120-volt outlet.
3. Turn on the power to the shot clocks and/or scoreboard(s)
4. Place the system in DIAGNOSTIC MODE and turn on every digit and indicator:
5. With the controller and the shot clocks and/or scoreboard(s) ON, press and hold the
OPTION key while turning the controller ON. The controller’s LCD will read: SELECT
DIAG MODE <SEGMENT TEST>
6. Press ENTER. The controller’s LCD will read: SEGMENT TEST <ALL SEGMENTS
OFF>