Warning
To avoid false readings, which could lead to possible
electric shock or personal injury, replace the battery as
soon as the battery indicator (
) appears.
To prevent damage or injury, install only replacement
fuses with the specified ratings.
Disconnect the test leads before opening the back
cover or the battery cover.
To replace battery, remove the screws on the battery cover
and remove the battery cover. Replace the exhausted
battery with a new one of the same type (9V, 6F22 or
equivalent). Reinstall the battery cover and the screws.
This meter uses two fuses:
Fuse1: 250mA, 250V, Fast action, Ø5X20mm
Fuse 2: 10A, 250V, Fast action, Ø5X20mm
To replace the fuse, remove the meter from its holster,
remove the battery cover and the battery, remove the
screws on the back cover and move the back cover
aside gently. Replace the blown fuse with a new one of
the same ratings. Reinstall the back cover and all its
screws, then reinstall the battery, the battery cover, and
the battery cover's screws. Reinstall the holster.
32
Replacing the Battery and Fuse
Summary of Contents for EM3672