background image

Power Cord

MM2) 

3×1.5 

3×1.5 

3×1.5 

  Above data is subject to modification without notice. 

Note: 

The above data is adapted to power cord ≤ 10m. If power cord is

10m, wire diameter 

must be increased. The signal cable can be extended to 50m at most.   

Pay attention: 

Please  ensure  the  safety  of 
the power plug. 

Otherwise,  it  could  cause 
electric shock or fire.

 

Do  not  disconnect  the  power 
supply  while  the  machine  is 
running 

Otherwise,  it  could  cause  an 
electric shock or fire. 

 

Do  not  use  damaged  or 
substandard wires. 

Otherwise, it could cause an 
electric shock or fire. 

 

After all connections are complete and checked, perform the following steps: 

1)  The user should start the water pump first to ensure no water leakage in the water pipe 

system; then set the thermostat at the appropriate temperature after power on. 

2)  In order to protect the machine, it has a delayed start function, after start up, the  water 

pump  start,  next  fan  runs,  and  the  compressor  will  start  up  automatically  after  about  3 
minutes 

3)  Check if there is any abnormal noise when running 
4)  Check that the set temperature is appropriate 
 

Depending on the initial temperature of the pool water and the  air temperature, it may take 
several days to heat the water to the desired temperature. A good swimming pool cover can 
greatly reduce the time required. 

Time delay - the heat pump has a built-in 3-minute start delay (only started when heated) to 

protect  the  circuit  and  avoid  frequent  switches  causing  losses.  The  machine  will  restart 

automatically  after  the  delay  period.  Even  a  brief  power  outage  can  trigger  this  delay  and 

prevent the machine from restarting immediately. Power on and off during this delay does not 

affect the 3-minute duration of the delay. 

1.5 Condensate water 

The air entering the heat pump is strongly cooled when heat pump heat the pool water, 
which  may  cause  condensation  of  the  evaporator  fins.  At  higher  relative  humidity, 

Summary of Contents for POOLSTYLE GHD-150-0318

Page 1: ...INSTALLATION AND USER MANUAL P O O L S T Y L E...

Page 2: ......

Page 3: ...Power Supply 5 1 5 Condensate water 6 2 Dimension 7 3 Technical Parameter 8 4 Operation instruction 9 4 1 Temperature display 9 4 2 Operation 9 5 Trouble Shooting 10 5 1 Trouble shooting for common fa...

Page 4: ...do not try to repair it yourself otherwise it may cause danger The main power switch should be placed in a position that children cannot reach in order to prevent children from playing with the main p...

Page 5: ...alled or removed by professionals and it is forbidden to dismantle and refit without permission b Don t put obstacles before the air inlet and outlet of the heat pump 2 Installation a This product mus...

Page 6: ...c The unit must be far away from any source of fire d Storage place must be bright wide open and good ventilation ventilation equipment is required 4 Maintenance Notice a If maintenance or scrap is re...

Page 7: ...Stable power supply 3 Pool filter This heat pump should be installed in a well ventilated place outside and the distance from the swimming pool should be greater than or equal to 2 meters The machine...

Page 8: ...damage the heat pump 1 3Connection 1 4Power Supply Before connecting the power supply make sure that the power supply matches the rated power supply of the product Cable Selection of the Protection De...

Page 9: ...ayed start function after start up the water pump start next fan runs and the compressor will start up automatically after about 3 minutes 3 Check if there is any abnormal noise when running 4 Check t...

Page 10: ...reach several litters per hour This phenomenon is sometimes mistaken for a leak 2 Dimension A B C D E GHD 150 0318 367 412 425 190 49 GHD 150 0319 445 484 503 300 49 GHD 150 0320 445 484 503 300 49 N...

Page 11: ...Water 26 C Humidity 80 Heating capacity kW 3 3 5 8 7 0 Performance Condition Air 15 C Water 26 C Humidity 70 Heating capacity kW 2 2 3 8 4 8 Power supply 230V 50Hz 1PH Advised water flux m 1 2 2 3 3...

Page 12: ...turn off 2 Water temperature Adjustment When the heat pump is on press or to modify the setting temperature of the water 3 During heating will be light the water temperature can be adjusted to 18 40 4...

Page 13: ...above solutions don t work please contact your installer with detailed information and your model number Don t try to repair it yourself Note If the following conditions happen please stop the machine...

Page 14: ...strictly forbidden to use volatile oil gasoline thinner and other substances f Please clean the swimming pool and filtration system regularly to avoid damage to the unit due to filter clogging g With...

Page 15: ...2 the electrical box it must be confirmed that all the indicators in the electrical box have been extinguished before operation...

Page 16: ......

Page 17: ...Version C40Mr32...

Reviews: