3.3. Output Setup

Select the output channel you wish to edit by pressing the channel button below the VU meter for the
corresponding channel once. Make the first settings with the output turned low or muted. 
To toggle through the different items, press the Item Up or Item Down buttons.

3.3.1. Gain

Adjust the gain by dialing the rotary encoder. The gain is adjusted in steps of 0.25dB. Smaller steps (0.01dB)
can be set via the PC or MAC interface.

3.3.2. Mixer

Turn the rotary encoder to mix the signal from the selected input to the selected output. Push the rotary
encoder to select the input. Attention: The mixer is only available while the outputs are not linked by Channel
Link. If the channels are linked, the mixer will be skipped.

3.3.3. Delay

Set the delay time by turning the encoder. Select the displayed unit (ms or s, mm or m, feet, inches, or mils)
by pushing the encoder.

3.3.4. Low Pass Filter

Adjust the Low Pass Filter frequency by turning the rotary encoder. You can switch the low pass filter off by
turning the rotary encoder up (clockwise) until the frequency passes 20kHz. 
Press the rotary encoder to change the filter type. Select the type by turning the rotary encoder. You can
choose from: Butterworth 6dB, Bessel 6dB, Butterworth 12dB, Bessel 12dB, Linkwitz Riley12dB, Butterworth
18dB, Bessel 18dB, Butterworth 24dB and Bessel 24dB. Higher order filters may be set by adding filter
sections in the PEQ blocks (see below).

3.3.5. High Pass Filter

Adjust the high pass frequency by dialing the rotary encoder. You can switch the high pass filter off by dialing
the rotary encoder down (counterclockwise) until the frequency passes 20Hz.
Press the rotary encoder to change the filter type. Select the type by turning the rotary encoder. You can
choose from: Butterworth 6dB, Bessel 6dB, Butterworth 12dB, Bessel 12dB, Linkwitz Riley12dB, Butterworth
18dB, Bessel 18dB, Butterworth 24dB and Bessel 24dB. Higher order filters may be set by adding filter
sections in the PEQ blocks (see below).

Page 10/13

Summary of Contents for ASP-4M8

Page 1: ...ALLDSP ASP 4M8 User Manual for ALLDSP ASP 4M8 Page 1 13...

Page 2: ...el controls Alternatively the ASP 4M8 can be configured completely via a remote connection to a PC MAC iPad or iPhone Please refer to the Software User Manual for details on the remote control applica...

Page 3: ...urce at installation Connect this equipment only to the power source indicated on the equipment rear panel To reduce the risk of fire or electric shock refer servicing to qualified service personnel o...

Page 4: ...buttons allow direct access to all editing and navigating functions See section three for a detailed description on the functions of each of these buttons 1 1 4 Rotary Encoder The rotary encoder is u...

Page 5: ...o input channels on one electronically balanced XLR connector The input will accept AES3 input signals at 44 1 48 88 2 or 96kHz An internal asynchronous sample rate converter ASRC converts the sample...

Page 6: ...lication has an auto discovery tool that will automatically connect to any unit found on the network Please refer to the Software Manual available on our website for details on the control software No...

Page 7: ...put level control From the crossover there may be additional filters that are employed to improve the response of your speakers There may also be limiters set up to keep your amplifiers from going int...

Page 8: ...t the input channel you wish to edit by pressing the channel button below the VU meter for the corresponding channel once Make the first settings with the output turned low or muted To toggle through...

Page 9: ...g the rotary encoder Press the rotary encoder to select the parameters The available parameters are Frequency 20Hz to 20kHz Gain 12dB to 12dB Q 0 2 to 25 Enabled On or Off Type Bell High Shelf Low She...

Page 10: ...ss Filter Adjust the Low Pass Filter frequency by turning the rotary encoder You can switch the low pass filter off by turning the rotary encoder up clockwise until the frequency passes 20kHz Press th...

Page 11: ...in dB Oct 3 3 7 Compressor The compressor is a true RMS compressor Turn the rotary encoder to set the threshold Press the rotary encoder to select the parameters The available parameters are Threshol...

Page 12: ...ncoder and confirm by pushing it To cancel push the exit button Now your preset is saved in the selected location The presets contain all filter dynamics gain settings etc in other words everything th...

Page 13: ...entical to the original fuse If you want to dispose this product do not mix it with general household waste There is a separate collection system for used electronic products in accordance with legisl...