background image

ALLDSP ASP-4M8

Appendix A: Declaration Of Conformity

DECLARATION OF CONFORMITY
ALLDSP GmbH & Co. KG
Kueferstrasse 18
59067 Hamm
Germany 
declares that the product: ASP-4M8
 
conforms to the following Product Specifications:

Safety: IEC 60065 -01+Amd 1
EMC : EN 55022:2006
EN 55103 -1, -2 2008
EN 55024:1998
FCC Part 15
Supplementary Information:
The product herewith complies with the requirements of the: 
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC.
RoHS Directive 2002/95/EC
WEEE Directive 2002/96/EC
With regard to Directive 2005/32/EC and EC Regulation 1275/2008 of 17 December 2008, this product is
designed, produced, and classified as Professional Audio Equipment and thus is exempt from this Directive.

A molded mains plug that has been cut off from the cord is unsafe. Discard the mains plug at a suitable
disposal facility. NEVER UNDER ANY CIRCUMSTANCES SHOULD YOU INSERT A DAMAGED OR CUT
MAINS PLUG INTO A POWER SOCKET. Do not use the mains plug without the fuse cover in place.
Replacement fuse covers can be obtained from your local retailer. Only use replacement fuses that are
identical to the original fuse.

If you want to dispose this product, do not mix it with general household waste. There is a separate collection
system for used electronic products in accordance with legislation that requires proper treatment, recovery
and recycling. Private household in the 25 member states of the EU, in Switzerland and Norway may return
their used electronic products free of charge to designated collection facilities or to a retailer (if you purchase
a similar new one). For Countries not mentioned above, please contact your local authorities for a correct
method of disposal. By doing so you will ensure that your disposed product undergoes the necessary
treatment, recovery and recycling and thus prevent potential negative effects on the environment and human
health.

ELECTROMAGNETIC COMPATIBILITY
This device complies with part 15 of the FCC Rules and the Product Specifications noted on the Declaration
of Conformity. Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired
operation. Operation of this processor within significant electromagnetic fields should be avoided.
- use only shielded interconnecting cables.

Page 13/13

Summary of Contents for ASP-4M8

Page 1: ...ALLDSP ASP 4M8 User Manual for ALLDSP ASP 4M8 Page 1 13...

Page 2: ...el controls Alternatively the ASP 4M8 can be configured completely via a remote connection to a PC MAC iPad or iPhone Please refer to the Software User Manual for details on the remote control applica...

Page 3: ...urce at installation Connect this equipment only to the power source indicated on the equipment rear panel To reduce the risk of fire or electric shock refer servicing to qualified service personnel o...

Page 4: ...buttons allow direct access to all editing and navigating functions See section three for a detailed description on the functions of each of these buttons 1 1 4 Rotary Encoder The rotary encoder is u...

Page 5: ...o input channels on one electronically balanced XLR connector The input will accept AES3 input signals at 44 1 48 88 2 or 96kHz An internal asynchronous sample rate converter ASRC converts the sample...

Page 6: ...lication has an auto discovery tool that will automatically connect to any unit found on the network Please refer to the Software Manual available on our website for details on the control software No...

Page 7: ...put level control From the crossover there may be additional filters that are employed to improve the response of your speakers There may also be limiters set up to keep your amplifiers from going int...

Page 8: ...t the input channel you wish to edit by pressing the channel button below the VU meter for the corresponding channel once Make the first settings with the output turned low or muted To toggle through...

Page 9: ...g the rotary encoder Press the rotary encoder to select the parameters The available parameters are Frequency 20Hz to 20kHz Gain 12dB to 12dB Q 0 2 to 25 Enabled On or Off Type Bell High Shelf Low She...

Page 10: ...ss Filter Adjust the Low Pass Filter frequency by turning the rotary encoder You can switch the low pass filter off by turning the rotary encoder up clockwise until the frequency passes 20kHz Press th...

Page 11: ...in dB Oct 3 3 7 Compressor The compressor is a true RMS compressor Turn the rotary encoder to set the threshold Press the rotary encoder to select the parameters The available parameters are Threshol...

Page 12: ...ncoder and confirm by pushing it To cancel push the exit button Now your preset is saved in the selected location The presets contain all filter dynamics gain settings etc in other words everything th...

Page 13: ...entical to the original fuse If you want to dispose this product do not mix it with general household waste There is a separate collection system for used electronic products in accordance with legisl...