5 Connecting the terminal to the distributor
© 2022 Interflex Datensysteme GmbH | IF Distributors | 06.22
17
5.2 Connecting the terminal to the distributor 75-90-2401
Each terminal is connected to an I/O controller board via terminal board.
Connecting the terminal to the I/O controller board
VCC +
COM-
COM+
Tx+
Tx-
V+
V-
BE
4
2
5
3
1
1
Cable shield (drain wire)
2
Connection cable to terminal/terminal
board
3
Terminal board
4
Clamp strap for shield at the distributor
5
I/O controller board
To connect the terminal:
1. Terminal board: Connect the shield and the drain wire
1
via the shield clamp
4
2. Terminal: Connect the drain wire with BE
3. Connect the connector board and the terminal as shown in the figure
4. Insert the plug of the cable
2
coming from the terminal into the female connector of the
terminal board