PegaSys Operating Modes
61
4 PegaSys Operating Modes
Ex works, the PegaSys Offline components are permanently configured for one of the following operating
modes:
§
"Teach in" PIN-Code
basic operating mode without credentials with code entry via keypad (only for
door fittings with keypad).
§
"Teach in" (P 100)
basic operating mode without software support with master credentials.
§
"'NetworkOnCard" (P 200 / P 300)
operating mode with software support.
4.1 Applicable reading technologies:
The PegaSys Offline components support the following reading technologies for the credentials:
§
MIFARE Classic
§
MIFARE DESFire
§
LEGIC Prime
§
LEGIC Advant
§
Hitag1 (availability depends on the type of PegaSys Offline component)
4.2 Switchover to daylight saving time, leap year
The PegaSys Offline components automatically switch to daylight saving time and back. The switchover is
performed in acc. with EU directive 2000/84/EC.
The PegaSys Offline components also detect leap years automatically.
4.3 »Teach in« PIN Code operating mode
In the case of PegaSys Offline components for the »
Teach in
«
PIN-Code
operating mode, all settings are
configured by entering codes at the integrated keypad.
Properties:
§
The door fitting can recognize up to 100 codes.
§
Using programming codes, you can:
- teach-in or delete new codes.
- adjust the door open time.
§
Security: If an incorrect code is entered three times, the door fitting is blocked for an adjustable period.
§
PegaSys Offline component signals when the batteries are getting weaker.
§
Credential data and settings stored in the memory are retained when the batteries are changed.
You can find more details on
PegaSys PIN-Code
in a separate manual.
4.4 »Teach in« (P 100) operating mode
In the case of PegaSys Offline components for the »
Teach in
«
(P 100) operating mode
, all settings are
programmed by means of a
master card
.
Device properties:
§
PegaSys Offline can recognize up to 100 credentials.
§
A credential can be enrolled at any number of PegaSys Offline components.
§
No data is written to these credentials.
§
With the master card, you can:
- Enroll new credentials.
- Delete individual credentials.
- Delete all credentials.
- Adjust the 'door open' time.
§
PegaSys Offline component signals when the batteries are getting weaker.
§
Credential data and settings stored in the memory are retained when the batteries are changed.
Summary of Contents for PegaSys
Page 2: ......
Page 4: ......
Page 7: ...Installation Instructions for PegaSys Electronic Door Fittings ...
Page 8: ......
Page 34: ......
Page 35: ...Installation Instructions for PegaSys Electronic Lock Cylinders ...
Page 36: ......
Page 52: ......
Page 53: ...Installation Instructions for PegaSys Electronic Locker Locks ...
Page 54: ......
Page 61: ...PegaSys Locker Locks 57 Locking lever type 4 6 5 mm angled ...
Page 63: ...PegaSys Teach In or NetworkOnCard Operation Valid for all PegaSys offline components ...
Page 64: ......
Page 78: ......
Page 83: ......