Electrified locks
Schlage • L-Series service manual • 179
Electrified LM-Series functions
No cylinder:
LM9290 – outside lever electrically locked/unlocked; LM9291 – both levers electrically locked/unlocked
Outside cylinder:
LM9292 – outside lever electrically locked/unlocked; LM9293 – both levers electrically locked/unlocked
Outside and inside cylinders:
LM9294 – outside lever electrically locked/unlocked; LM9295 – both levers electrically locked/unlocked
Request to exit (RX)
For L909x and L949x Series electrified locks:
A microswitch inside the lock case to detect rotation of the inside knob/lever. The switch then signals the use of the opening to
the security system. The RX is a removable module located on the bottom edge of the lock chassis. The module must be
properly positioned to detect inside knob/lever rotation. If not properly positioned, the lock and/or microswitch may be
damaged. Electrical rating: 3 A, 125 V AC; 2 A, 30 V DC. Order RX switch assembly by
L283-452
.
For L908x Series electrifed locks:
Locks shipped prior to mid-2010 are configured with two-wire switches:
L283-059
for normally closed or
L283-125
for
normally open L-Series, and
L283-197
for normally closed or
L283-196
for normally open LV-Series.
Note:
RX is not applicable for LM929X-Series locks.
Deadbolt monitoring
Deadbolt Monitor (DM) identifies the status of the deadbolt (extended or retracted). Normally open, normally closed, and
common connections are provided. Note: Deadbolt monitor is only available on deadbolt models. Electrical rating: 3 A,
125 V AC; 2 A, 30 V DC.
Latchbolt monitoring
Latchbolt Monitor (LX) identifies the status of the latchbolt (extended or retracted). Normally open, normally closed,
and common connections are provided. Electrical rating: 3 A, 125 V AC; 2 A, 30 V DC.
Latchbolt monitor function available for discontinued functions L9080 EL-RX, L9080 EU. Specify XL12-245 for
L9080PEL, or XL12-246 for L9080PEU.
Door position switch
Door Position Sensor (DPS) detects the position of the door, open or closed, by utilizing a sensor in the mortise lock to
detect a magnet located in the door strike. Normally open, normally closed, and common connections are provided.
Note: DPS is not available on deadbolt models. Max voltage 175 VDC, max current 0.250 A.