Lubrication specifications
Schlage • L-Series service manual • 183
LM9200 Series
Lock case lubrication areas
Subassembly and component
Lock case and case cover: Apply lubrication at shaded areas.
Top link:
Apply lubricant at shaded areas
indicated.
Tilting link:
Apply lubricant at shaded areas
indicated.
Bottom link:
Apply lubricant at
shaded areas
indicated.
Link subassembly:
Apply lubricant at shaded areas indicated.
After assembly of top link, bottom link and tilting link in the lock case,
brush lubricant to fill slots as shown.
Electrified
locks only:
DO NOT
lubricate
this area.
Retractor (LM9256 only):
Apply lubricant at shaded areas
indicated.
Spool subassemblies:
Apply lubricant at shaded areas
indicated.
Apply lubricant to lobes as
specified.
Lubricate lobes.
Use 5/32" hex
key to rotate
part 180°.Then,
lubricate the
opposite side.
DO NOT
lubricate
this area.