103 • Schlage • ENGAGE Managed Property User's Guide
Device Defaults
Web Application
Control Mobile Enabled Smart Lock
Fig. 8.103: Control Default Settings
Table 8.10 Control Mobile Enabled Smart Lock Property Wide Settings
Setting
Description
Beeper Enabled
When set to ON the lock beeper will sound to provide device status. When set to OFF
the lock beeper will remain silent.
Relock Delay
When a valid credential is presented, this is the time the deadbolt thumb turn is
engaged for locking and unlocking. Delayed relocks are from 1 – 30 seconds.
Mobile Credential • ON: Lock will accept Mobile Credential access and the following options are
available.
• OFF: Mobile Credential use is disabled
Communication
Range
Enables the Schlage Mobile Credential application to find locks from short or longer
distances.
Note:
Î
This is a PACS only feature. This setting has no effect on ENGAGE
accounts.
Performance
This setting effects how often the device scans for a Mobile Credential.
• Normal: Default
• Max: Highly recommended for best user experience and quicker device unlocking
when using Mobile Credentials. Max setting will reduce battery life by a few months
as the device scans more frequently.