126 • Schlage • ENGAGE Managed Property User's Guide
Control Mobile Enabled Smart Lock
Installation and Commissioning
Factory Default Reset (FDR) Overview
A Factory Default Reset (FDR) will return the Control Mobile Enabled Smart Lock to its original
settings as shipped from the factory.
Additionally, the following will occur.
• The device will beep once when the inside lever is turned.
• Removes any non-default device settings, deletes any construction or user credentials, and allows
construction mode to be entered again.
• Does
NOT
have any effect on the firmware currently on the device.
• Does
NOT
remove the Control Mobile Enabled Smart Lock from your ENGAGE account.
Perform a Factory Default Reset (FDR)
1. Remove inside cover.
2. Disconnect at least 1 battery for 10 seconds.
3. Reconnect batteries.
4. Wait for the lock to beep and flash GREEN 3 times.
5. Within 10 seconds, rotate the interior tailpiece back and forth 2 times.
a. The lock flashes 1 long GREEN flash and beeps 1 long beep to indicate success.
Fig. 11.7: Interconnect
Fig. 11.8: Deadbolt
Verify Success of the FDR
The Control Mobile Enabled Smart Lock will “advertise” its presence via Bluetooth communication
after FDR.
When properly reset, the Control Mobile Enabled Smart Lock will advertise its presence via its
Bluetooth radio and is available for commissioning again.
Construction Mode Overview
The Construction Mode is used to allow access before the lock is commissioned or during testing
before commissioning.
• Construction Mode is a temporary mode of operation and is NOT required to be used.
• Construction Mode is enabled by default and after a successful Factory Default Reset (FDR).
• The lock will remain in Construction Mode until the mode is cancelled by a Factory Default Reset
(FDR) or the device is commissioned into ENGAGE.
• No access audits are captured while the lock is in Construction Mode because the lock does not
track time or credential numbers.
• Control devices will use the credential “Facility Code” as the Construction Credential ID.
• All credentials with the same Facility Code as the originally presented credential, will be allowed
access during Construction Mode.
Images show the
older version of
Control, but the FDR
process remains the
same.