84 • Schlage • ENGAGE Managed Property User's Guide
Devices
Web Application
Table 8.4 NDE80 and NDEB Device Settings
Setting
Description
Settings Tab
Name
The name of the device
Relock Delay
(seconds)
Immediately after unlocking, set the lock to automatically relock itself between 1 – 30
seconds.
ADA Relock Delay
(seconds)
Enables ADA operation to allow additional time to access doors. Delayed relocks are
from 1 – 225 seconds.
Record Propped
Door Audit After
Reports and records a Propped Door Audit after a specified time. Delayed relocks are
from 1 – 255 seconds.
Power Fail Mode
Defines what the lock should do when entering Critical Battery Mode.
• Secure : Locked
• Passage: Unlocked
• AS IS: no change
Schedules
Assign schedules
“First-Person-In”
Unlocks Door
The First Person-in rule keeps a door locked until after a scheduled unlocked AND a
valid credential has been presented. The door will then unlock and remain unlocked
until the scheduled relock time. This feature prevents access until a valid user is
present.
Holidays
Assign Holidays
Beeper Enabled
• ON: the lock beeper will sound to provide device status.
• OFF: the lock beeper will remain silent
Reader Tab
Credential
Reader: Prox in
Use
Choose the technology used by readers in your site:
• Schlage (HID)
• AWID
• GE/CASI
• GE4001
• GE4002
Credential
Reader: Smart in
Use
Choose the technology used by readers in your site:
• 14443 UID (CSN)
• 14443 Secure MiFare
• 14443 Secure MiFare Plus
• 14443 EV1 (NOC)
• 15693 UID (CSN)
• iClass 40 Bit UID (CSN)
Reader Sensitivity • Set to Normal by default and is recommended for most properties.
• Use a Reader Sensitivity of High or Max to enable a more reliable reading of
physically smaller key fobs due to smaller antenna.
Mobile Credential Tab
Mobile Credential • OFF: Mobile Credential use is disabled.
• ON: lock will accept Mobile Credential access
Communication
Range
Enables the Schlage Mobile Credential application to find locks from short or longer
distances.
Note:
Î
This is a PACS only feature. This setting has no effect on ENGAGE
accounts.
Performance
Affects how often the device scans for a Mobile Credential.
• Normal: Default
• Max: Highly recommended for best user experience and quicker device unlocking
when using Mobile Credentials. Reduces battery life by a few months as the device
scans more frequently.
For best reader
response and
improved battery life,
disable any credential
technology that is not
needed.
Notice that as you
enable certain
settings, other
settings are disabled.
Some settings conflict
and therefore cannot
be enabled at the
same time.