105 • Schlage • ENGAGE Managed Property User's Guide
Device Defaults
Web Application
LE and LEB
Fig. 8.105: LE Default Settings
Table 8.12 LE and LEB Device Property Wide Settings
Setting
Description
Beeper Enabled
• ON: the lock beeper will sound to provide device status.
• OFF: the lock beeper will remain silent.
Relock Delay
(seconds)
When a valid credential is presented, the locking device unlocks and then relocks.
Delayed relocks are from 1 – 30 seconds.
ADA Relock Delay
(seconds)
Enables ADA operation to allow additional time to access doors. Delayed relocks are
from 1 – 30 seconds.
Propped Door
Delay (seconds)
Reports and records a Propped Door Audit after a specified time. Delayed relocks are
from 1 – 255 seconds.
Power Fail Mode
Defines what the lock should do when entering Critical Battery Mode.
• Secure : Locked
• Passage: Unlocked
• AS IS: no change
Blink Interior LED
• ON: the Interior LED will blink while in Privacy Mode to inform the occupant of the
secured status.
• OFF: default
Blink Interior LED
rapidly
• ON: increases how often the Inside LED is flashing for better visibility.
• OFF: default
Mobile Credential • OFF: Mobile Credential use is disabled.
• ON: lock will accept Mobile Credential access and the following options are
available.
Communication
Range
Enables the Schlage Mobile Credential application to find locks from short or longer
distances.
Note:
Î
This is a PACS only feature. This setting has no effect on ENGAGE
accounts.
Performance
Affects how often the device scans for a Mobile Credential.
• Normal: Default
• Max: Highly recommended for best user experience and quicker device unlocking
when using Mobile Credentials. Reduces battery life by a few months as the device
scans more frequently.