HOOD REMOVAL AND REPLACEMENT INSTRUCTIONS FOR P/N’S 9910 & 9910R
1. Exit from the hazardous environment and remove the supplied air hood.
2. Turn off the air supply and disconnect the breathing tube from the air line hose at the waist.
3. Unbuckle and remove the waist belt.
4. Remove the plastic hose clamp from the hood and breathing tube.
5. Remove the breathing tube from the hood. Dispose of the hood.
6. Install the breathing tube into the replacement hood. Be sure to insert the breathing tube
fully into the collar of the hood. (See drawing “Underside View
”
)
Underside View for 9910 & 9910R
7. Install the white clamp over both the hood and breathing tube. Squeeze the clamp until
the clamp teeth engage. Be sure that the clamp is
snug so the breathing tube does not
disengage.
WARNING!
Do not kink or crush the breathing tube. This could restrict airflow and allow the user to be
exposed to contaminants.
8. Return to instructions for putting on (donning) the respirator.
HOOD REMOVAL AND REPLACEMENT INSTRUCTIONS FOR
P/N’s 9910D & 9910DS
Summary of Contents for 9910 Series
Page 12: ......